EasyManua.ls Logo

Hitachi RAC-14EH1 - Page 84

Hitachi RAC-14EH1
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82
LD301 blinks 2 times.
Peak current-cut.
Is the intelligent power
module (IPM) normal?
Replace the intelligent power
module (the main P.W.B.).
LD301 blinks 1 time.
Reset stop.
However, the unit always resets and
stops just after power is supplied:
\this does not indicate a fault.
Is the reset circuit normal?
Normally, pin 7 of
CN18 is approx. 5V.
Replace the main P.W.B.
Make sure again that
connectors are connected
securely.
Perform final operation
check.
Ye s
Ye s
Ye s
No
No
07B065_RAS-14EH1_061-082_E 2007.2.6, 9:31 AM82

Other manuals for Hitachi RAC-14EH1

Related product manuals