EasyManua.ls Logo

Hitachi RAC-18WPE User Manual

Hitachi RAC-18WPE
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT
ROOM AIR CONDITIONER
OUTDOOR UNIT
SERVICE MANUAL
REFER TO THE FOUNDATION MANUAL
TECHNICAL INFORMATION
SPECIFICATIONS
CONTENTS
SPECIFICATIONS ------------------------------------------------------------------- 6
CONSTRUCTION AND DIMENSIONAL DIAGRAM ---------------------- 9
MAIN PARTS COMPONENT --------------------------------------------------- 11
WIRING DIAGRAM ---------------------------------------------------------------- 13
After installation
BLOCK DIAGRAM ----------------------------------------------------------------- 16
REFRIGERATING CYCLE DIAGRAM --------------------------------------- 17
DESCRIPTION OF MAIN CIRCUIT OPERATION ----------------------- 20
SERVICE CALL Q & A ---------------------------------------------------------- 37
TROUBLE SHOOTING ------------------------------------------------------------41
OUTDOOR UNIT
PROCEDURE FOR DISASSEMBLY AND REASSEMBLY-------------19
PARTS LIST AND DIAGRAM
--------------------------------------------------56
NO.0120E
RAC-18WPE
RAC-42WPE
Johnson Controls-Hitachi Air Conditioning Wuhu Co., Ltd.
JCH-WH
OUTDOOR UNITOUTDOOR UNIT OUTDOOR UNIT
RAC-25W
RAC-42W
(KW)
(B.T.U./h)
(KW)
(B.T.U./h)
W
750(+65)
792(+85)
H
548
600
D
288(+27.5)
299(+47)
MODEL
POWER SOURCE
TOTAL INPUT (W
TOTAL AMPERES (A)
CAPACITY
COOLING
HEATING
TOTAL INPUT (W
TOTAL AMPERES (A)
CAPACITY
DIMENSIONS
(mm)
1,120 (300 1,700)
32.5
NET WEIGHT
TYPE
DC INVERTER
1 PHASE,50H z ,220-230V
5.10-4.88
4.20 (1.70 5.00)
14,330 (5,800 17,060)
18,430 (5,800 20,470)
5.99-5.73
1,317 (500 2,100)
5.40 (1.70 6.00)
PE
RAC-18W
750(+65)
548
288(+27.5)
419 (250 1,010)
32.5
1 PHASE,50H z ,220-230V
2.46-2.35
519 (250 970)
2.93-2.81
8,530 (3,070 10,920)
2.00 (0.90 2.5)
6,820 (3,070 8,530)
2.50 (0.90
3.20)
733 (250 1500)
3.87-3.71
11,600 (3,070 15,010)
8,530 (3,070 10,580)
3.40 (0.90
4.40)
PE
RAC-35W
750(+65)
548
288(+27.5)
941 (250
1,460)
32.5
1 PHASE,50H z ,220-230V
4.81-4.60
1,000 (250 1,700)
5.11-4.89
14,330 (3,070 17,060)
3.50 (0.90 4.00)
11,940 (3,070 13,650)
4.20 (0.90
5.00)
PE
PE
1 PHASE,50H z ,220-230V
549 (250 1,290)
3.08-2.95
2.50 (0.90
3.10)
39
OUTDOOR UNIT OUTDOOR UNIT
RAC-50W
792(+85)
600
299(+47)
1,471 (300
2,100)
6.69-6.40
5.00 (1.90 5.20)
17,060 (6,480 17,740)
20,470 (7,510 24,910)
7.09-6.78
1,558 (500 2,750)
6.00 (2.20 7.30)
PE
1 PHASE,50H z ,220-230V
39
FOR SERVICE PERSONNEL ONLY
RAC-25WPE
RAC-35WPE
RAC-50WPE
RA
C-18WPE
RAC-25WPE
RAC-35WPE
RAC-42WPE
RAC-50WPE
1
Question and Answer IconNeed help?

Do you have a question about the Hitachi RAC-18WPE and is the answer not in the manual?

Hitachi RAC-18WPE Specifications

General IconGeneral
BrandHitachi
ModelRAC-18WPE
CategoryAir Conditioner
LanguageEnglish

Summary

Specifications

Model and Power Source

Details of model numbers and power source requirements for outdoor units.

Cooling and Heating Capacity

Specifies cooling and heating capacities in kW and BTU/h.

Dimensions and Net Weight

Provides physical dimensions and net weight of outdoor units.

Safety During Repair Work

Semiconductor Handling Standards

Scope and Object Parts

Defines the scope and identifies object parts for handling standards.

Handling Precautions

Outlines essential precautions for handling semiconductor parts safely.

Operating Cautions

Outdoor Unit Electrical Specifications

Component Specifications

Lists detailed electrical specifications for various outdoor unit components.

Outdoor Unit Installation Guidelines

Construction and Dimensional Diagrams

RAC-18/25/35WPE Outdoor Unit Dimensions

Shows detailed dimensions and installation clearances for specific outdoor unit models.

RAC-42/50WPE Outdoor Unit Dimensions

Shows detailed dimensions and installation clearances for specific outdoor unit models.

Main Parts Components

Thermostat and Fan Motor

Details components like thermostat and fan motor specifications.

Outdoor Unit Electric Components

Lists main electric components used in the outdoor unit.

Compressor Motor Specifications

Wiring Diagrams

RAC-18/25/35WPE Wiring Diagram

Electrical schematic for the RAC-18/25/35WPE outdoor unit.

RAC-42/50WPE Wiring Diagram

Electrical schematic for the RAC-42/50WPE outdoor unit.

Block Diagram

Outdoor Unit System Overview

Provides a functional overview of the outdoor unit's control system.

Refrigerating Cycle Diagrams

RAC-18/25/35WPE Refrigeration Cycle

Illustrates cooling and heating cycles for specific models.

RAC-42/50WPE Refrigeration Cycle

Illustrates cooling and heating cycles for specific models.

Disassembly and Reassembly Procedures

RAC-18/25/35WPE Disassembly Steps

Step-by-step guide for disassembling electrical parts of specific models.

RAC-42/50WPE Disassembly Steps

Step-by-step guide for disassembling electrical parts of specific models.

Main Circuit Operation Description

Power Circuit Operation (RAC-18/25/35WPE)

Explains the function of the main power circuit for specific models.

Low Voltage Power Circuit

Details the low voltage power supply circuits and their functions.

Power Circuit P.W.B. Specifications

Lists voltage specifications and checking points for the power circuit.

Reversing Valve (4-Way Valve) Control Circuit

Temperature Detection Circuit

Electric Expansion Valve Circuit

Outdoor DC Fan Motor Control Circuit

Fan Motor Diagnosis and Checks

Procedure for diagnosing fan motor issues and troubleshooting steps.

Power Circuit Operation (RAC-42/50WPE)

Low Voltage Power Circuit

Details the low voltage power supply circuits and their functions for RAC-42/50WPE.

Power Circuit P.W.B. Specifications

Lists voltage specifications and checking points for the power circuit.

Service Call Q&A

Cooling Operation Q&A

Addresses common questions and answers related to cooling operation issues.

Dehumidification Q&A

Provides answers to frequently asked questions about dehumidification mode.

Heating Operation Q&A

Addresses common questions and answers regarding heating operation.

Auto-fresh Defrost Q&A

Explains the auto-fresh defrost function and related user queries.

Automatic Operation Q&A

Answers questions about automatic operation mode selection and behavior.

Common Operation Issues

Covers general operational queries like noise, wind speed, and startup behavior.

Wireless Remote Control Operations

Timer Setting Issues

Addresses problems with setting and using timers on the remote control.

Current Time Display

Explains behavior related to the current time display on the remote.

Timer Reservation Issues

Discusses problems encountered when making timer reservations.

Sleep Timer Reservation

Covers issues with setting the sleep timer alongside other timers.

Sleep Timer and Operation Modes

Addresses sleep timer functionality and limitations in specific modes.

Temperature Setting Display

Explains the temperature display behavior on the remote control.

Vertical Vane Button Functionality

Clarifies the behavior of the vertical vane button on the remote.

Troubleshooting Inspection Instructions

Power Circuit Discharge and Safety

Connector Handling Instructions

Receptacle Detaching and Reattaching

Guides on safely detaching and reattaching tab terminal receptacles.

Board Connector Handling

Instructions for detaching and reattaching board connectors with locking mechanisms.

Connector Handling Warning

Critical warning against handling connectors while the unit is energized.

Troubleshooting Support

Outdoor Unit Error Display

Explains how failure modes are displayed on the outdoor unit via blinking lamps.

Self-Diagnosis Memory Function

Describes the self-diagnosis memory and how to access stored failure modes.

Self-Diagnosis Lighting Mode (RAC-18/25/35WPE)

Troubleshooting by Blinking Codes

Lists self-diagnosis blinking codes, their meanings, and repair actions.

Self-Diagnosis Lighting Mode (RAC-42/50WPE)

Troubleshooting by Blinking Codes

Lists self-diagnosis blinking codes, their meanings, and repair actions.

Outdoor Unit Electrical and Refrigerating Cycle Troubleshooting Flowchart

LD301 Blinking Code Troubleshooting (RAC-18/25/35WPE)

EEPROM Reading Error Troubleshooting

Steps for diagnosing EEPROM reading errors indicated by LD301 blinking 13 times.

Communication Error Troubleshooting

Steps for diagnosing communication errors indicated by LD301 blinking 9 times.

Other LD301 Blinking Code Issues

Addresses other LD301 blinking patterns and their troubleshooting.

LD301 Blinking Code Troubleshooting (RAC-42/50WPE)

EEPROM Reading Error Troubleshooting

Steps for diagnosing EEPROM reading errors indicated by LD301 blinking 13 times.

Communication Error Troubleshooting

Steps for diagnosing communication errors indicated by LD301 blinking 9 times.

Other LD301 Blinking Code Issues

Addresses other LD301 blinking patterns and their troubleshooting.

LD301 Blinking Code Troubleshooting (Continued)

Power Supply Voltage Error

Steps for diagnosing power supply voltage errors indicated by LD301 blinking 10 times.

Thermistor Abnormality Troubleshooting

Steps for diagnosing thermistor abnormalities indicated by LD301 blinking 7 times.

OH Thermistor Rise Troubleshooting

Steps for diagnosing OH thermistor issues indicated by LD301 blinking 6 times.

High Load Stop Troubleshooting

Steps for diagnosing high load stops indicated by LD301 blinking 16 times.

LD301 Blinking Code Troubleshooting (Continued)

Overload Lower Limit Cut Troubleshooting

Diagnosing overload lower limit cuts indicated by LD301 blinking 5 times.

Switchover Failure Troubleshooting

Diagnosing switchover failures indicated by LD301 blinking 4 times.

Abnormally Slow Rotation Troubleshooting

Diagnosing slow rotation indicated by LD301 blinking 3 times.

Peak Current Cut Troubleshooting

Diagnosing peak current cuts indicated by LD301 blinking twice.

LD301 Blinking Code Troubleshooting (Continued)

Active Voltage Abnormality Troubleshooting

Diagnosing active voltage abnormalities indicated by LD301 blinking 14 times.

Fan Lock Stop Troubleshooting

Diagnosing fan lock stops indicated by LD301 blinking 12 times.

Fan Stopped Due to Strong Wind Troubleshooting

Diagnosing fan stops due to strong wind indicated by LD301 blinking 11 times.

Checking the Refrigerating Cycle

Troubleshooting Procedure (No Operation)

Procedure for diagnosing issues when the unit is not operating, heating, or cooling.

Outdoor Unit Test Switch Operation

Running Outdoor Unit Independently

Instructions on how to operate the outdoor unit using the test switch.

How to Operate the Outdoor Unit Independently

RAC-18/25/35WPE Independent Operation Setup

Steps for setting up independent operation for specific models.

RAC-42/50WPE Independent Operation Setup

Steps for setting up independent operation for specific models.

Parts List and Diagram - Outdoor Unit (RAC-18/25/35WPE)

RAC-18/25/35WPE Outdoor Unit Parts Diagram

Exploded view diagram showing parts for RAC-18/25/35WPE outdoor units.

Indoor Unit Parts List

Indoor Unit Parts Identification

Lists parts for indoor units with corresponding part numbers.

Parts List and Diagram - Outdoor Unit (RAC-42/50WPE)

RAC-42/50WPE Outdoor Unit Parts Diagram

Exploded view diagram showing parts for RAC-42/50WPE outdoor units.

Outdoor Unit Parts List (RAC-42/50WPE)

Outdoor Unit Parts Identification (RAC-42/50WPE)

Lists parts for RAC-42/50WPE outdoor units with part numbers.