ELECTRICAL DATA
21
6 ELECTRICAL DATA
6.1. INDOOR UNIT
Model
Unit Main Power Applicable Current Indoor Fan Motor
VOL, PH, Hz Fuse Rating (A) STC RNC RNC IPT
RAK-18RPB 230, 1, 50 3.15 (C) 3.34 (H) 3.49 (C) 4.39 (H) 4.22 0.67 30
RAK-25RPB 230, 1, 50 3.15 (C) 4.36 (H) 4.56 (C) 5.61 (H) 5.43 0.67 30
RAK-35RPB 230, 1, 50 3.15 (C) 5.27 (H) 5.51 (C) 6.35 (H) 7.39 0.67 30
RAK-50RPB 230, 1, 50 3.15 (C) 7.59 (H) 7.93 (C) 9.13 (H) 11.96 0.67 30
VOL: Rated Unit Power Supply Voltage (V) RNC: Running Current (A)
Hz: Frequency (Hz) PH: Phase (φ)
STC: Starting Current (A) IPT: Input (W)
6.2. OUTDOOR UNIT
Model
Unit Main Power Compressor Motor
VOL, PH, Hz Fuse Rating (A) Min (V) Max (V) Locked Rotor Ampere (A) STC
Cooling Operation Heating Operation
RNC IPT RNC IPT
RAC-18WPB 230, 1, 50 15 207 253
-
3.49 4.39 550 4.22 580
RAC-25WPB 230, 1, 50 15 207 253
-
4.56 5.61 700 5.43 880
RAC-35WPB 230, 1, 50 15 207 253
-
5.51 6.35 1090 7.39 1100
RAC-50WPB 230, 1, 50 25 207 253
-
7.59
9.13 1560 11.96 1660
VOL: Rated Unit Power Supply Voltage (V) RNC: Running Current (A)
HZ: Frequency (Hz) PH: Phase (φ)
STC: Starting Current (A) IPT: Input (W)
NOTE:
1. The above compressor data is based on 100% capacity combination of indoor units at the rated operating frequency
2. This data is based on the same conditions as the nominal heating and cooling capacities.
3. The compressor started by an inverter, resulting in extremely low starting current.