5. Heat exchanger temperature thermistor circuit
● The circuit detects the indoor heat
exchanger temperature and controls
the following.
(1) Low-temperature defrosting during
cooling and dehumidifying
operation.
The voltage at A depends on the heat
exchanger temperature as shown in
Fig. 5-2.
6. Temporary Switch
● The temporary switch is used to operate the air conditioner temporarily when the wireless remote control
is lost or faulty.
● The air conditioner operates in the previous mode at the previously set temperature. However, when the
power switch is set to OFF, it starts automatic operation.
INDICATION P.W.B.