CAUTION
!
The Choice of Mounting Site (Please note the following matters and obtain permission from customer before installation).
Dimension of Mounting Stand
of the Outdoor unit
(unit : mm)
3
Bush
Names of Outdoor Components
QtyNo. Item
Drain Pipe
1
Bush
1
A circuit breaker or fuse must be installed. Without a circuit breaker or fuse the danger of electric shock exists.
The external switch shall be incorporated to completely disconnect from power supply. It should disconnect all
poles, and a contact separation of at least 3mm must be present.
Do not install the unit near a location where there is ammable gas. The outdoor unit may catch
re if ammable gas leaks around it.
Do not install the indoor unit in a machine shop or kitchen where vapor from oil or its mist ows to the indoor
unit. The oil will deposit on the heat exchanger, thereby reducing the indoor unit performance and may deform
and in the worst case, break the plastic parts of the indoor unit.
Please ensure smooth ow of water when installing the drain hose.
Piping shall be suitable supported with a maximum spacing of 1m between the supports.
mounting stand
Figure showing the Installation of Outdoor Unit.
This unit is chargeless up 30m pipe length.
Installation of pipe length less than minimum pipe length
requirement (3 meters) may generate an abnormal sound.
CAUTION
The difference in height
between the indoor and
outdoor unit should be
kept max 20m.
The connecting pipe,
no matter big or small,
should all be insulated
with insulation pipe and
then wrapped with vinyl
tape. (The insulator will
deteriorate if it is not
wrapped with tape).
The connection of insulated
drain hose.
Please use insulated drain
hose for the indoor piping
(commercial product).
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the
insulator is insufficient,
please use commercial
products).
Be sure to
completely
seal any gap
with putty.
above 100mm
above 300mm
about
400mm
must not bend
Maximum pipe length 30m
Minimum pipe length 3m
above 200mm
above 100mm
give
clearance
as wide as
possible
above 100mm
above 700mm
above 200mm
inner diameter ø 16mm
<IA1575: B >
1
2
3
This symbol shows that this
equipment uses a ammable
refrigerant.
If the refrigerant is leaked,
together with an external
ignition source, there is a
possibility of ignition.
This symbol shows that the
Operation Instructions should
be read carefully.
This symbol shows that a
service personnel should be
handling this equipment with
reference to the Installation
Manual.
This symbol shows that there
is information included in
the Operation Manual and/or
Installation Manual
WARNING
CAUTION
CAUTION
CAUTION
!
BURST HAZARD
Do not allow air, etc. to get
into refrigerant cycle (piping)
RISK OF EXPLOSION
Compressor must be stopped
before removing refrigerant
pipes.
All service valve must be fully
closed after pumping down
operation.
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer. Any un t method or using incompatible material may cause product damage, burst and serious
injury.
The appliance/pipe-work shall be stored in a well ventilated room with indoor oor area larger than A
min
[refer
to Table 1] and without any continuously operating ignition source. Keep away from open ames, any operating
gas appliances or any operating electric heater. Else, it may explode and cause injury or death.
The appliance/pipe-work shall be installed, and/or operated in a room with oor area larger than A
min
[refer to
Table 1] and keep away from ignition sources, such as heat/spark/open ame or hazardous areas such as gas
appliances, gas cooking, reticulated gas supply systems or electric cooking appliances, etc.
Do not pierce or burn as the appliance/pipe-work is pressurized. Do not expose the appliance/pipe-work to heat,
ame, sparks, or other sources of ignition. Else, it may explode and cause injury or death.
WARNING
!
Refrigerant piping
must be protected
from physical
damage. Install a
plastic cover or
equivalent.
Flare connection only at outside
of building
WARNING
!
Table 1: Minimum Floor area of the room A
min
(m
2
)
Minimum Floor area of the room
A
min
(m
2
)
Max refrigerant
charge amount
(g)
Max Piping
Length
(m)
Outdoor
Model
RAC-E70YHA
RAC-E80YHA
30
30
1600
1600
2.44
2.44
1.63
1.63
WARNING
!
The Outdoor unit must be mounted at a location which can support
heavy weight. Otherwise, noise and vibration will increase.
CAUTION
!
Do not expose the unit under direct sunshine or rain. Besides,
ventilation must be good and clear of obstruction.
The air blown out of the unit should not point directly to animals
or plants.
The clearances of the unit from top, left, right and front are
speci ed in gure below. At least 3 of the above sides must be
open air.
Be sure that the hot air blown out of the unit and noise do not
disturb the neighbourhood.
Do not install at a location where there is ammable gas, steam,
oil and smoke.
The location must be convenient for water drainage.
Place the Outdoor unit and its connecting cord at least 1m away
from the antenna or signal line of television, radio or telephone.
This is to avoid noise interference.
Do not install outdoor unit facing strong wind direction. It may
damage the fan motor.
Do not install the outdoor unit in a place where small animals
may build their nests. If small animal goes inside the unit and
touches the electrical parts, failure of the unit, smoke or re may
be caused. Request your customer to keep the surrounding of
the unit is clean.
OUTDOOR UNIT
RAD-E**YHARAI-E**YHARAS-E**YHA
Tools Needed For Installation Work
WARNING
!
Carefully read through the procedures of
proper installation before starting installation
work.
The sales agent should inform customers
regarding the correct operation of installation.
(
mark is tool exclusive use for R32)
+ – Screwdriver
Measuring Tape
Knife
Saw
Pipe Cutter
Hexagonal Wrench Key ( 4mm)
Power Drill (ø 65mm ~ ø 80mm)
Vacuum Pump
Pliers or Wrench
Torque Wrench Vacuum Pump Adaptor
Flare Tool
Gas Leakage Detector
Manifold Valve Charge Hose
Reamer
File
Flare nut must use a torque wrench without fail. Tighten with the speci ed tightening
torque. If the are nut is tightened too much, after a long period of time, the are nut
breaks, Gas leakage, stagnation, touching re, rarely cause ignition.
Sharp bending of the pipe use the polyethylene rod, bend not crushed the pipe. Gas
leakage from the crushed part, stagnation, touching re, rarely cause ignition.
Please request your sales agent or quali ed technician to install your unit. Water
leakage, short circuit or re may occur if you do the installation work yourself.
Please observe the instructions stated in the installation manual during the process of
installation. Improper installation may cause water leakage, electric shock and re.
A brazed, welded, or mechanical connection shall be made before opening the valves to
permit refrigerant to ow between the refrigerating system parts. A vacuum valve shall
be provided to evacuate the interconnecting pipe and/or any uncharged refrigerating
system part.
Mechanical connectors used indoors shall comply with ISO 14903. When mechanical
connectors are reused indoors, sealing parts shall be renewed. When ared joints are
reused indoors, the are part shall be re-fabricated.
Refrigerant tubing shall be protected or enclosed to avoid damage.
Make sure that the units are mounted at locations which are able to provide full support
to the weight of the units. If not, the units may collapse and impose danger.
Observe the rules and regulations of the electrical installation and the methods described
in the installation manual when dealing with the electrical work. Use power cables
approved by the authorities of your country.
Be sure to use the speci ed wire for connecting the indoor and outdoor units. Please
ensure that the connections are tight after the conductors of the wire are inserted into
the terminals. Improper insertion and loose contact may cause over-heating and re.
Please use the speci ed components for installation work. Otherwise, the units may
collapse or water leakage, electric shock and re may occur.
Be sure to use the speci ed piping set for R32. Otherwise, this may result in broken
copper pipes or faults.
When installing or removing an air conditioner, only speci ed refrigerant (R32) shall be
allowed, do not allow air or moisture to remain in the refrigeration cycle. Otherwise,
pressure in the refrigeration cycle may become abnormally high so that a rupture may
be caused.
Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas
comes into contact with re, a poisonous gas may occur. Be aware that refrigerants
may not contain an odour.
After completion of installation work, check to make sure that there is no refrigeration
gas leakage. If the refrigerant gas leaks into the room, coming into contact with re
in the fan-driven heater, space heater, etc., a poisonous gas may occur.
Unauthorized modi cations to the air conditioner may be dangerous. If a breakdown
occurs please call a quali ed air conditioner technician or electrician. Improper repairs
may result in water leakage, electric shock and re, etc.
<
IA1575: B
>
SAFETY PRECAUTION
Read the safety precautions carefully before operating the unit.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING ........ Incorrect methods of installation may cause death or serious injury.
CAUTION ......... Improper installation may result in serious consequence.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating
the unit as described in the user’s guide.
!
!
Refrigerant pipe size (outer diameter): Narrow pipe, Liquid (ø6.35mm); Wide pipe, Gas (ø15.88mm)



INSTALLATION
MANUAL
SPLIT UNIT AIR CONDITIONER
OUTDOOR UNIT
RAC-E70YHA
RAC-E80YHA
EN INSTRUCTION MANUAL
FOR SERVICE
PERSONNEL ONLY
!
Question and Answer IconNeed help?

Do you have a question about the Hitachi RAC-E70YHA and is the answer not in the manual?

Overview

This document provides comprehensive installation instructions for the HITACHI SPLIT UNIT AIR CONDITIONER, specifically models RAC-E70YHA and RAC-E80YHA, which utilize R32 refrigerant. It is intended for service personnel only and emphasizes safety precautions, proper mounting, electrical connections, and refrigerant piping procedures.

Function Description

The device is a split-unit air conditioner designed for cooling and heating purposes. It consists of an indoor unit and an outdoor unit, connected by refrigerant piping and electrical wiring. The system uses R32 refrigerant, which is a flammable refrigerant, necessitating strict adherence to safety guidelines during installation and maintenance to prevent leaks and potential ignition. The outdoor unit is responsible for heat exchange with the ambient air, while the indoor unit conditions the air within the room.

Important Technical Specifications

  • Refrigerant Type: R32 (flammable refrigerant).
  • Refrigerant Pipe Size (Outer Diameter):
    • Narrow pipe (Liquid): Ø6.35mm
    • Wide pipe (Gas): Ø15.88mm
  • Maximum Piping Length: 30 meters.
  • Minimum Piping Length: 3 meters (installation of pipe length less than 3 meters may generate abnormal sound).
  • Maximum Refrigerant Charge Amount: 1600g for both RAC-E70YHA and RAC-E80YHA models.
  • Minimum Floor Area of the Room (Amin):
    • RAC-E70YHA: 2.44 m² (RAS-EYHA), 1.63 m² (RAI-EYHA, RAD-E**YHA)
    • RAC-E80YHA: 2.44 m² (RAS-EYHA), 1.63 m² (RAI-EYHA, RAD-E**YHA)
  • Maximum Height Difference between Indoor and Outdoor Unit: 20 meters.
  • Power Supply: The unit requires a dedicated power supply, and the voltage and current specifications should be checked against the model's requirements. For example, a 230V, 50Hz supply is mentioned for certain regions.
  • Circuit Breaker: A circuit breaker or fuse must be installed, with an external switch capable of completely disconnecting from the power supply, ensuring all poles are disconnected and a contact separation of at least 3mm is present.
  • Piping Support: Piping shall be suitably supported with a maximum spacing of 1m between supports.

Usage Features

The manual primarily focuses on installation rather than user operation. However, it emphasizes that after installation, the unit should operate in proper condition, and the customer should be explained the correct way of operating the unit as described in the user's guide. The system is designed for both cooling and heating, providing year-round comfort.

Maintenance Features

The manual highlights several aspects related to maintenance and safety:

  • Refrigerant Leakage Check: After installation, it is crucial to check for any refrigerant gas leakage. If refrigerant gas leaks into the room and comes into contact with fire (e.g., from a fan-driven heater or space heater), a poisonous gas may be produced.
  • Flare Nut Tightening: Flare nuts must be tightened with a torque wrench to the specified torque. Overtightening can cause the flare nut to break over time, leading to gas leakage.
  • Pipe Bending: When bending pipes, a polyethylene rod should be used to prevent crushing, which could lead to gas leakage.
  • Electrical Connections: All electrical connections must be tight to prevent overheating and fire.
  • Cleaning and Defrosting: Users are warned not to use means to accelerate the defrosting process or to clean the unit other than those recommended by the manufacturer, as unfit methods or incompatible materials can cause product damage, bursts, and serious injury.
  • Storage and Installation Environment: The appliance and pipe-work must be stored and installed in a well-ventilated room with a floor area larger than the specified Amin (refer to Table 1) and without any continuously operating ignition sources (open flames, gas appliances, electric heaters). This is critical due to the flammable nature of R32 refrigerant.
  • Protection of Refrigerant Piping: Refrigerant piping must be protected from physical damage, for example, by installing a plastic cover or equivalent.
  • Insulation: The indoor piping should be insulated with the enclosed insulation pipe, and if insufficient, commercial products should be used. All connecting pipes, regardless of size, should be insulated and then wrapped with vinyl tape to prevent insulator deterioration.
  • Drainage: Smooth flow of water must be ensured when installing the drain hose, and an insulated drain hose (commercial product) should be used for indoor piping.
  • Professional Service: Unauthorized modifications are dangerous. In case of a breakdown, a qualified air conditioner technician or electrician should be called, as improper repairs can lead to water leakage, electric shock, and fire.
  • Compressor Safety: The compressor must be stopped before removing refrigerant pipes, and all service valves must be fully closed after pumping down operation to prevent air from entering the refrigerant cycle, which could cause a burst hazard or explosion.