– 53 –
Notes:
(1) Condition for entering into Hot Dashed mode. When fan set to Hi or Auto mode and i) Indoor temperature is lower than 18°C, and ii) outdoor temperature is lower than 10°C,
and iii) Temperature difference between indoor temperature and set temperature has a corresponding compressor rpm (calculated value in Table 3) larger than WMAX.
(2) Hot Dashed will release when i) Room temperature has achieved the set temperature + SFTDSW. ii) Thermo off.
(3) During Hot Dashed operation, thermo off temperature is set temperature (with shift value) +3°C. After thermo off, operation continue in Fuzzy control mode.
(4) Compressor minimum ON time and OFF time is 3 minutes.
(5) During normal heating mode, compressor maximum rpm WMAX will maintain for 120 minutes if indoor temperature is higher than 18°C. No time limit constrain if indoor temperature
is lower than 18°C and outdoor temperature is lower than 2°C.
(6) During Hotkeep or Defrost mode, indoor operation lamp will blink at interval of 3 seconds ON and 0.5 second OFF.
(7) When heating mode starts, it will enter into Hotkeep mode if indoor heat exchanger temperature is lower than YNEOF + 0.33°C.
(8) When fan is set to Med or Lo, compressor rpm will be limited to WBEMAX.
(9) In Ultra-Lo fan mode, if indoor temperature is lower than 18°C, indoor fan will stop. If indoor temperature is higher than 18°C + 0.33°C, fan will continue in Ultra-Lo mode.
During Hotkeep or Defrost mode, fan will continue in Ultra-Lo mode.
(10) During Hot Dashed or outdoor temperature is lower than 5°C, compressor rpm is WMAX2.
(11) During Hot Dashed, when room temperature reaches set temperature + SFTDSW compressor rpm is actual rpm x DWNRATEW.
Temperature Calculated
difference compressor rpm
1.66 1965 min
1
2 2135 min
1
2.33 2300 min
1
2.66 2465 min
1
3 2635 min
1
3.33 2800 min
1
3.66 2965 min
1
4 3135 min
1
4.33 3300 min
1
4.66 3465 min
1
5 3635 min
1
5.33 3800 min
1
5.66 3965 min
1
6 4135 min
1
6.33 4300 min
1
6.66 4465 min
1
7 4635 min
1
7.33 4800 min
1
7.66 4965 min
1
8 5135 min
1
8.33 5300 min
1
8.66 5465 min
1
9 5635 min
1
9.33 5800 min
1
9.66 5965 min
1
10 6135 min
1
10.33 6300 min
1
10.66 6465 min
1
11 6635 min
1
Table 3 TWMAX
Notes:
1. See the data in Table 1 on
page 45 for each constant in
capital letters in the diagrams.
0274E Pg 53(RAI-50NH5) 19/10/05, 3:32 PM1