The installation height of indoor unit must be 2.3m or more.
!
CAUTION
Figure showing the Installation of Indoor and Outdoor unit.
(
)
above 200mm
above 700mm
above 50mm when
installed on the
ceiling of balcony
above 100mm
Maximum pipe length 20m
Minimum pipe length 5m
above 100mm
give clearance as
wide as possible
above 200mm
Drain Pipe
Must be installed separately.
Insulate indoor part of pipe
to prevent condensation.
● The difference in height
between the indoor and
outdoor unit should be
kept below 5m.
● The connecting pipe, no
matter big or small,
should all be insulated
with insulation pipe and
then wrapped with vinyl
tape. (The insulator will
deteriorate if it is not
wrapped with tape).
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the
insulator is insufficient,
please use commersial
products)
Be sure to
completely
seal any
gap with
putty.
– 5 –
0274E Pg 1-5(RAI-50NH5) 19/10/05, 2:44 PM6