EasyManua.ls Logo

Hitachi RAK-25PEB - DISASSEMBLY AND REASSEMBLY PROCEDURES; Indoor Unit Fan Motor Removal; Outdoor Unit Electrical Parts Removal

Hitachi RAK-25PEB
111 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL RAC-18/25/35WEB
4. T
angential air flow fan and fan motor
T
T
Fig. 4
Fig. 6
Fig. 8
Fi
g. 9
Fig. 10
Fi
g. 5
Lower bearing cover
Cabinet
(
Press to lower the hook at the center of the unit a little and pull the
claw
f
orward to remove the drain pan.
(5) Remove the electrical box fixing screws and GND wire fixing
scre
w
.
( )
Remove P lock which binds lead wires.
( S
et the electrical box upside down.
(
Remove P.
W
.B. fixing screws (2 locations) and radiation fin fixing
screws
(
locations
)
, and remove the P
.W
.B.
f
rom the support.
1. Electr
i
cal Part
s
(
1
)
R
emove the upper cover
f
ixing screws and li
f
t the cover to remove it.
(
2
)
Remove the service valve cover
.
(
3
)
Remove the terminal plate cover
.
(4) Remove the right side cover
.
(2) Remove the screw from the upper and lower bearing covers.
(3) Remove the locking hook of the lower bearing cover from the
Cab
in
et.
(
Remove two lock screws from the fan motor holder
.
( ) Pull up the evaporator by holding it at the lower side. Insert a
screw driver through the space between the evaporator and drain
chute and loosen the
f
an lock screw to remove the
f
an motor.
<OUTDOOR UNIT>
Radiation fin fixing screw
P.W.B. fixing screw
Fi
g. 7
7
6
7)
8)
right side cover.
terminal cover.
valve cover.
1)
4)
5
41

Related product manuals