s 0LEASEREQUESTYOURSALESAGENTORQUALIlEDTECHNICIANTOINSTALLYOURUNIT7ATERLEAKAGESHORTCIRCUITORlREMAYOCCURIFYOUDOTHE
INSTALLATIONWORKYOURSELF
s 0LEASEOBSERVETHEINSTALLATIONSTATEDINTHEINSTALLATIONMANUALDURINGTHEPROCESSOFINSTALLATION)MPROPERINSTALLATIONMAYCAUSE
WATERLEAKAGEELECTRICSHOCKANDlRE
s -AKESURETHATTHEUNITSAREMOUNTEDATLOCATIONSWHICHAREABLETOPROVIDEFULLSUPPORTTOTHEWEIGHTOFTHEUNITS)FNOTTHEUNITSMAY
COLLAPSEANDIMPOSEDANGER
s /BSERVETHERULESANDREGULATIONSOFTHEELECTRICALINSTALLATIONANDTHEMETHODSDESCRIBEDINTHEINSTALLATIONMANUALWHENDEALING
WITHTHEELECTRICALWORK5SECABLESWHICHAREAPPROVEDOFlCIALINYOURCOUNTRY"ESURETOUSETHESPECIlEDCIRCUIT!SHORTCIRCUITAND
lREMAYOCCURDUETOTHEUSEOFLOWQUALITYWIREORIMPROPERWORK
s "ESURETOUSETHESPECIlEDCABLESFORCONNECTINGTHEINDOORANDOUTDOORUNITS0LEASEENSURETHATTHECONNECTIONSARETIGHTAFTERTHE
CONDUCTORSOFTHEWIREAREINSERTEDINTOTHETERMINALSTOPREVENTTHEEXTERNALFORCEISBEINGAPPLIEDTOTHECONNECTIONSECTIONOFTHE
TERMINALBASE)MPROPERINSERTIONANDLOOSECONTACTMAYCAUSEOVERHEATINGANDlRE
s 0LEASEUSETHESPECIlEDCOMPONENTSFORINSTALLATIONWORK/THERWISETHEUNITMAYCOLLAPSEORWATERLEAKAGEELECTRICSHOCKlREOR
STRONGERVIBRATIONMAYOCCUR
s "ESURETOUSETHESPECIlEDPIPINGSETFOR2!/THERWISETHISMAYRESULTINBROKENCOPPERPIPESORFAULTS
s 7HENINSTALLINGORTRANSFERRINGANAIRCONDITIONERTOANOTHERLOCATIONMAKESURETHATAIROTHERTHANTHESPECIlEDREFRIGERANT2!
DOESNOTENTERTHEREFRIGERATIONCYCLE)FOTHERAIRSHOULDENTERTHEPRESSURELEVELOFTHEREFRIGERATIONCYCLEMAYINCREASEABNORMALLY
WHICHCOULDRESULTINARUPTUREANDINJURY
s "ESURETOVENTILATEFULLYIFAREFRIGERANTGASLEAKWHILEATWORK)FTHEREFRIGERANTGASCOMESINTOCONTACTWITHlREAPOISONOUSGASMAY
OCCUR
s !FTERCOMPLETIONOFINSTALLATIONWORKCHECKTOMAKESURETHATTHEREISNOREFRIGERATIONGASLEAKAGE)FTHEREFRIGERANTGASLEAKSINTOTHE
ROOMCOMINGINTOCONTACTWITHlREINTHEFANDRIVENHEATERSPACEHEATERETCAPOISONOUSGASMAYOCCUR
s 5NAUTHORIZEDMODIlCATIONSTOTHEAIRCONDITIONERMAYBEDANGEROUS)FABREAKDOWNOCCURSPLEASECALLAQUALIlEDAIRCONDITIONER
TECHNICIANORELECTRICIAN)MPROPERREPAIRSMAYRESULTINWATERLEAKAGEELECTRICSHOCKANDlREETC
s "ESURETOCONNECTTHEEARTHLINEFROMTHEPOWERSUPPLYWIRETOTHEOUTDOORUNITANDBETWEEN
THEOUTDOORANDINDOORUNIT$ONOTCONNECTTHEEARTHLINETOTHEGASTUBEWATERPIPELIGHTINGRODORTHEEARTHLINEOFTHE
TELEPHONEUNIT)MPROPEREARTHINGMAYCAUSEELECTRICSHOCKS
s 7HENlNISHINGTHEREFRIGERANTCOLLECTIONPUMPINGDOWNSTOPTHECOMPRESSORANDTHENREMOVETHECOOLANTPIPE
)FYOUREMOVETHEREFRIGERANTPIPEWHILETHECOMPRESSORISOPERATINGANDTHESERVICEVALVEISRELEASEDAIRISSUCKEDANDA
PRESSUREINTHEFREEZINGCYCLESYSTEMWILLBUILDUPSTEEPLYCAUSINGANEXPLOSIONORINJURY
s 7HENINSTALLINGTHEUNITBESURETOINSTALLTHEREFRIGERANTPIPEBEFORESTARTINGTHECOMPRESSOR
)FTHEREFRIGERANTPIPEISNOTINSTALLEDANDTHECOMPRESSORISOPERATEDWITHTHESERVICEVALVERELEASEDAIRISSUCKEDANDTHE
PRESSURELEVELOFTHEREFRIGERATIONCYCLEMAYINCREASEABNORMALLYWHICHCOULDRESULTINARUPTUREANDINJURY
s !CIRCUIT BREAKERMUSTBE INSTALLEDIN THEHOUSE DISTRIBUTIONBOXFORTHEDIRECT CONNECTEDPOWER SUPPLYCABLESTO THEOUTDOOR UNIT
)NCASEOFOTHERINSTALLATIONSA MAINSWITCHWITH ACONTACTGAPORMORE THANMMHASTOBEINSTALLED7ITHOUTACIRCUIT BREAKER THE
DANGEROFELECTRICSHOCKEXISTS
s
$ONOTINSTALLTHEUNITNEARALOCATIONWHERETHEREISmAMMABLEGAS4HEOUTDOORUNITMAYCATCHlRE
IFmAMMABLEGASLEAKSAROUNDIT
s 0LEASEENSURESMOOTHmOWOFWATERWHENINSTALLINGTHEDRAINHOSE)MPROPERINSTALLINGMAYWETYOURFUNITURE
s !N)%#APPROVEDPOWERCORDSHOULDBEUSED0OWERCORDTYPE.9-
.O )TEM
1TY
1
2
5
3
2
4
5
6
7
2
L.H
12
310
299
500
792
330
INDOOR UNIT
CAUTION
FOR SERVICE PERSONNEL ONLY
WARNING
Indoor Unit / Outdoor Unit
RAK-18PSPA/RAC-18WSPA
RAK-25PSPA/RAC-25WSPA
RAK-35PSPA/RAC-35WSPA
s 2EADTHESAFETYPRECAUTIONSCAREFULLYBEFOREOPERATINGTHEUNIT
s 4HECONTENTSOFTHISSECTIONAREVITALTOENSURESAFETY0LEASEPAYSPECIALATTENTIONTOTHEFOLLOWINGSIGN
WARNING .......... Incorrect methods of installation may cause death or serious injury.
CAUTION .......... Improper installation may result in serious consequence.
Make sure to connect earth line.
This sign in the figures indicates prohibition.

"ESURETHATTHEUNITOPERATESINPROPERCONDITIONAFTERINSTALLATION%XPLAINTOCUSTOMERTHEPROPEROPERATIONANDMAINTENANCEOF
THEUNITASDESCRIBEDINTHEUSERgSGUIDE!SKACUSTOMERTOKEEPTHISINSTALLATIONMANUALTOGETHERWITHTHEINSTRUCTIONMANUAL
SAFETY PRECAUTION
WARNING
WARNING WARNING
CAUTION
CAUTION
CAUTION
THE CHOICE OF MOUNTING SITE
0LEASENOTETHEFOLLOWINGMATTERSANDOBTAINPERMISSIONFROMCUSTOMERBEFOREINSTALLATION
INDOOR UNIT
OUTDOOR UNIT
s 4HEUNITSHOULDBEMOUNTEDATSTABLENONVIBRATORYLOCATION
WHICHCANPROVIDEFULLSUPPORTTOTHEUNIT
s 4HE/UTDOOR UNITMUST BEMOUNTED ATA LOCATIONWHICH
CANSUPPORTHEAVYWEIGHT/THERWISENOISEANDVIBRATION
WILLINCREASE
s .ONEARBYHEAT SOURCE ANDNO OBSTRUCTION NEARTHE AIR
OUTLETISALLOWED
s 4HECLEARANCE DISTANCESFROM TOPRIGHTAND LEFTARE
SPECIlEDINlGUREBELOW
s 4HELOCATION MUSTBE CONVENIENTFOR WATERDRAINAGEAND
PIPECONNECTIONWITHTHE/UTDOORUNIT
s 4OAVOIDINTERFERENCEFROM NOISEPLEASE PLACETHE UNIT
ANDITS REMOTECONTROLLER ATLEAST MFROM THERADIO AND
TELEVISION
s 4OAVOIDANYERROR INSIGNAL TRANSMISSIONFROM THEREMOTE
CONTROLLERPLEASE PUTTHE CONTROLLERFARAWAYFROMHIGH
FREQUENCYMACHINESANDHIGHPOWERWIRELESSSYSTEMS
s $ONOT EXPOSETHEUNIT UNDERDIRECT SUNSHINEOR RAIN
"ESIDESVENTILATIONMUSTBEGOODANDCLEAROFOBSTRUCTION
s 4HEAIR BLOWNOUTOF THEUNIT SHOULDNOT POINTDIRECTLY TO
ANIMALSORPLANTS
s 4HECLEARANCESOFTHEUNITFROMTOPLEFTRIGHTANDFRONTARE
SPECIlEDINlGUREBELOW!TLEASTTHREEOFTHEABOVESIDES
MUSTBEOPENAIR
s 4HEINSTALLATIONHEIGHTSHOULDBEATLEASTMMORMORE
FROMTHEmOOR
s "ESURETHATTHEHOTAIRBLOWNOUTOFTHEUNITANDNOISEDO
NOTDISTURBTHENEIGHBOURHOOD
s $ONOTINSTALLATALOCATIONWHERETHEREISmAMMABLEGAS
STEAMOILANDSMOKE
s 4HELOCATIONMUSTBECONVENIENTFORWATERDRAINAGE
s 0LACETHE /UTDOORUNIT ANDITS CONNECTINGCORD ATLEAST
M AWAY FROM THEANTENNA ORSIGNAL LINEOF TELEVISION
RADIOORTELEPHONE4HISISTOAVOIDNOISEINTERFERENCE
.AMESOF)NDOOR#OMPONENTS
$IRECTIONOF0IPING
$IMENSIONOF-OUNTING
3TANDOFTHE/UTDOORUNIT
7HENTHEPOWERIS
SUPPLIEDFROMTHE
INDOORUNITPULLTHE
POWERCABLEFROMTHE
CABLEDRAWERATTHE
RIGHTORLEFTSIDEOF
THEINDOORUNIT
#ABLEDRAWERRIGHTSIDE
4HEREARE DIRECTIONSALLOWED
NAMELY BACKWARDPIPING
BACKWARDPIPING FROMLEFT
HORIZONTALLYPIPINGFROM RIGHT
HORIZONTALLYPIPINGFROM LEFT
VERTICALLYDOWNFROMRIGHTVERTICALLY
DOWNFROMLEFT
"ACKWARDPIPING
FROMLEFT
#ONNECTION
(ANGER
3CREWFOR(ANGER
!!!SIZE"ATTERY
2EMOTE#ONTROLLER
)NSULATIONSHEET
2EMOTE#ONTROLLER(OLDER
3CREWFOR2EMOTE
#ONTROLLER(OLDER
UNITMM
-OUNTING
3TAND
Figure showing the Installation
of Indoor and Outdoor Unit.
ABOVE
MM
Ć
ABOVEMM
Ć
ABOVEMM
0LUG
"ESURETO
COMPLETELY
SEALANYGAP
WITHPUTTY
ABOUTMM
MUSTNOTBEND
ABOUTM
MMORMORE
1
2
3
4
6
7
-AXIMUMPIPELENGTHM
-INIMUMPIPELENGTHM
4HEINDOORPIPINGSHOULD BE
INSULATEDWITHTHE ENCLOSED
INSULATIONPIPE)F THE INSULATOR IS
INSUFlCIENTPLEASEUSECOMMERCIAL
PRODUCTS
s 4HE REFRIGERATINGMACHINEOIL IS
EASILYAFFECTEDBYMOISTURE5SE
CAUTIONTOPREVENTWATER FROM
ENTERINGTHECYCLE
s 4HEDIFFERENCEINHEIGHTBETWEEN
THEINDOORAND OUTDOOR UNIT
SHOULDBEKEPTBELOWM
s 4HE CONNECTINGPIPENOMATTER
BIGORSMALL SHOULD ALL BE
INSULATEDWITHINSULATIONPIPEAND
THENWRAPPEDWITHVINYLTAPE
4HEINSULATORWILLDETERIORATEIFIT
ISNOTWRAPPEDWITHTAPE
4HECONNECTIONOFINSULATED DRAIN
HOSE
0LEASEUSEINSULATEDDRAIN HOSE FOR
THEINDOORPIPINGCOMMERCIAL
PRODUCT
)NNERDIAMETERMM
Ć
GIVECLEARANCEASWIDEASPOSSIBLE
Ć
ABOVEMM
ABOVE
MM
Ć
ABOVEMM
ABOVEMM
ABOVEMM
4HECLEARANCESOF THE
UNITFROM TOP LEFTRIGHT
ANDFRONTARE SPECIlED
INlGUREBELOW!TLEAST
THREEOFTHEABOVE
SIDESMUSTBEOPENAIR
Ć
GIVECLEARANC
ASWIDEAS
POSSIBLE
ABOVEMMWHEN
INSTALLEDONTHE
CEILINGOFBALCONY

1 2Installation of Hanger, Wall Penetration and Installation of Protection Pipe Installation Of The Indoor Unit
s 4HEDRAINING OFTHE WATERCONTAINERINSIDE THE)NDOOR UNITCAN BEDONE FROMTHE
LEFT4HEREFORETHE HANGERMUST BElXEDHORIZONTALLY ORSLIGHTLY TILTEDTOWARDSTHE
SIDEOFDRAINHOSE/THERWISECONDENSEDWATERMAYOVERmOWTHEWATERCONTAINER
Direct Mounting On The Wall
Procedures of Installation and Precautions
Installation Of Remote Controller
Wall Penetration and Installation of Protection Pipe
s 0LEASEUSEHIDDENBEAMSINTHEWALLTOHOLDTHEHANGER
6ISIBLEOUTLINEOFTHE
OUTDOORUNIT
$RAIN(OSE
,EVEL
,INE
7EIGHT
MM
MM
7ALLHOLE
(ANGER
3CREWFOR(ANGER
1
2
3CREWTHEHANGERATTHE
POSITIONSPOSSIBLYNEARTHE
UPPERANDLOWERHOOKSWHERE
THEINDOORUNITISHUNG5SEOR
MORESCREWSTOlXTHEHANGER
s0ROCEDURESTOlXTHEHANGER
s0ROCEDURESTOlXTHEHOLDEROFREMOTECONTROL
s 4HEREMOTECONTROLLERCANBEPLACEDINITSHOLDERWHICHISlXED
ONWALLORBEAM
s 4OOPERATETHE REMOTECONTROLLER AT ITSHOLDERPLEASEENSURE
THATTHE UNITCAN RECEIVESIGNALTRANSMITTED FROMTHE CONTROLLER
ATTHEPLACEWHERETHEHOLDERISTOBE
WHENSIGNAL ISRECEIVEDFROM THEREMOTE CONTROLLER4HESIGNAL
TRANSMISSIONISWEAKENBY THEFLUORESCENT LIGHT4HEREFORE
DURINGTHE INSTALLATIONOF THEREMOTE CONTROLHOLDERPLEASE
SWITCHONTHE LIGHTEVENDURINGDAYTIME TODETERMINETHE
MOUNTINGLOCATIONOFTHEHOLDER
s $RILLA MMHOLE ONWALL WHICHIS
SLIGHTLYTILTED TOWARDSTHEOUTDOOR SIDE
$RILLTHEWALLATASMALLANGLE
s #UTTHEPROTECTIONPIPEACCORDINGTOTHE
WALLTHICKNESS
s %MPTYGAPIN THE SLEEVEOF PROTECTION
PIPESHOULDBECOMPLETELYSEALED WITH
PUTTYTOAVOIDDRIPPINGOFRAINWATERINTO
THEROOM
s 0LEASEENSURESMOOTH FLOWOF WATER
WHENINSTALLING THEDRAINHOSE)MPROPER
INSTALLINGMAYWETYOURFUNITURE
s !N )%#APPROVEDPOWER CORDSHOULD BE
USED0OWERCORDTYPE.9-
s 4HERUBBER STRAPUSED FORFIXINGTHE
INSULATORSHOULD NOTBE TIEDWITH GREATFORCE
/THERWISETHISWILL DAMAGEHEAT INSULATION
ANDCAUSESWATERCONDENSATION
s 0LEASEPULLTHELOWERPARTOFTHE)NDOORUNIT
OUTWARDSTOCHECKIFTHEUNITISHOOKEDONTO
THEHANGER)MPROPERINSTALLATIONMAYCAUSE
VIBRATIONANDNOISE
s 4RANSFORMTHEPIPINGWHILEHOLDINGDOWNTHE
LOWERPORTIONOFPIPESUPPORTBYHAND
$RILLHOLESONWALL
!SSHOWNBELOW
$RILLHOLESONWALL
!SSHOWNBELOW
0USHPLUGINTOTHEHOLES
!SSHOWNBELOW
0USHPLUGINTOTHEHOLES
!SSHOWNBELOW
&IXTHEHANGERONWALLWITH
XSCREW!SSHOWN
INlGUREBELOW
7ALL
7ALL
7ALL
3CREW
3CREW
(ANGER
MM
MM
1
2
6
7
0LUG
0ROCURE
LOCALLY
0LUG0ROCURELOCALLY
#EILING
2EMOTE
#ONTROL
(OLDER
4HEREMOTECONTROLLER
MUSTBESLIDEINTHE
REMOTECONTROLLER
HOLDERINTHEDIRECTION
ASSHOWNINTHElGURE
UNTILITHOOKSATTHE
LOWERENDOFTHEREMOTE
CONTROLLERHOLDER
2EMOTE
#ONTROLLER
2EMOTE
#ONTROLLER
(OLDER
3CREWPIECES
)NDOOR
/UTDOOR
MM
3EALWITH
PUTTY
3EALWITH
PUTTY
0ROTECTION
PIPE
3LEEVEOF
PROTECTION
PIPE
7!,,
"ESURETHATTHEWIREISNOT
INCONTACTWITHANYMETALIN
THEWALL0LEASE USETHE
PROTECTIONPIPEAS WIRE
PASSINGTHROUGHTHEHOLLOW
PART OFTHE WALLSOAS TO
PREVENTTHE POSSIBILITYOF
DAMAGEDBYMOUSE
5NLESSITSEALSCOMPLETELY
ANYAIRWITH HIGHHUMIDITY
mOWSFROMOUTDOORANDANY
DEWMAYDROP
Cutting Low Cover bush
s 7HILEINSTALLINGTHEPIPEFROMTHERIGHTLEFTOR
BOTTOMSIDEUSE AKNIFETO CUTOPENINGS AS
SHOWNINlGURE4HENSMOOTHENTHEEDGESOF
OPENINGSWITHAlLE
Changed of Drain Hose and Installation Procedures.
s %XCHANGETHELOCATIONOFDRAINHOSEANDDRAINCAPWHILEINSTALLINGTHEPIPEFROMTHELEFTSIDEAS
SHOWNINBELOW"ESURETOPLUGINTHEDRAINHOSEUNTILTHEINSULATINGMATERIALFOLDSUPONITSELF
s #ONNECTCONNECTINGCORD
s 0ULLOUTTHEPIPECONNECTINGCORDANDDRAINHOSE
s )NSERTTHEPIPETHROUGHTHEWALLHOLE
s 4HEREFRIGERATINGPIPESANDCONNECTINGCORD
TRANSFORMANDAREATTACHED
1
4HEUPPER PART OFTHE )NDOORUNIT ISHANGED ONTHE
HANGER
2
4HEPROJECTION ATTHE LOWERPART OFTHE )NDOORUNIT IS
HOOKEDONTOTHEHANGER
/PENINGS
/PENINGS
1
PIPING FROM THE RIGHT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
2
PIPING FROM THE LEFT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
0REPARATION
)NSTALLATION
#ONNECTINGCORDSPIPEAND
DRAINHOSEMUSTBELAID
TOGETHERWITH6INYLTAPE
7ALLHOLE
0ROJECTION
0LIERS
$RAIN
(OSE
3CREW
0IPE
$RAINCAP
$RAINCAP
$RAINOUTLET
3OCKEHEAD
WRENCHMM
3OCKEHEAD
WRENCHMM
2UBBERSTRAPTIED
WITHGREATFORCE
4RANSFORMAFTER
BENDINGDOWNWARD
0IPE
SUPPORT
#ONNECTING#ORD
$RAIN(OSE
0ROTECTION
0IPE
2EFRIGERATING
0IPE
$RAINLAYOUTOF
BACKWARDPIPING
0IPE
0IPE
(ANGER
(ANGER
$RAINHOSE#ABLE
1
1
,IFTTHEBODY
OFTHEUNIT
UPWARDSAND
THENFORCEIT
DOWNWARDS
1
2
0REPARATION
s 0LEASEUSEPLIERSTOPULL
OUTTHEDRAINCAP4HISIS
ANEASIERWAYTOREMOVE
THEDRAINCAP
)NSUFFICIENTINSERTMAY
RESULTINWATERLEAKAGE
s0USHTHEPIPE DEEPLYUNTIL THE
INSULATINGSECTIONOFTHEDRAINHOSE
ENDGETSOVERTHE RIBATTHEINDOOR
UNITSIDEANDlXITBYSCREW
s2EMOVELOWCOVER
s5SESOCKETHEADWRENCH TO )NSERT
DRAINCAPUPTOTHELOCATIONSECURELY
TILLTHECAPSTOPS
$RAIN(OSE
INSTALLATION AFTER CONNECTION OF REFRIGERATING PIPES
THE CONNECTION OF REFRIGERATING PIPE DURING
THE INSTALLATION OF INDOOR UNIT
s 4HEREFRIGERATING PIPESHOULD BEADJUSTED TOlT INTO
THEHOLE ONTHE WALLANDTHEN READYFORFURTHER
CONNECTION
s 4HETERMINALSOFCONNECTEDPIPESMUSTBECOVERED
WITHINSULATORUSEDFORTERMINALCONNECTION4HENTHE
PIPESAREWRAPPEDWITHINSULATIONPIPE
s #ONNECTTHECONNECTING CORDAFTER REMOVINGLOW
COVER
2EFERTO#/..%#4)/./&0/7%2#/2$
s !FTERADJUSTMENTlTTHE CONNECTINGCORDANDPIPES
INTOTHESPACEAVAILABLEUNDERTHEUNIT5SEHOLDERTO
HOLDTHEMTIGHT
s (OLDERCAN BE ATTACHEDAT THEEITHER OF PLACES
0LEASESELECTTHEEASIERPOSITION
$RAINHOSE
0ROJECTION
0ROJECTION
PIPE
(OOK
ABOUTCM
(OLDER
BELOW
MM
MM
#ONNECTING
CORD
)NSULATIONPIPEMUSTBEWRAPPEDWITH
VINYLTAPEATEVERYMM
4HEENDOFTHEREFRIGERATINGPIPESAREAT
LOCATIONSMARKEDWITHh
vSYMBOL
0LEASEBENDATASMALL
RADIUSTOFORMANARC
0REPARATION4O)NSTALL2EFRIGERATING0IPES
)NSTALLATION
(ANGTHEINDOOR UNITONTO THEHANGER 5SETHE TEMPORARY STAND
ATTHE BACKOFTHE )NDOORUNIT TOPUSH ITSLOWERPART CM
FORWARDS
s 0LACETHEDRAINHOSETHROUGHTHEHOLEONTHEWALL
s 7RAPTHEREFRIGERATINGPIPESWITH INSULATION PIPEAFTER
CONNECTINGREFRIGERATINGPIPE
s #ONNECTTHECONNECTINGCORDAFTERREMOVINGLOWCOVER
2EFERTO#ONNECTIONOF0OWER#ORD
s !FTERADJUSTMENTTHECONNECTINGCORDANDREFRIGERATINGPIPES
AREPLACEDINTOTHESPACEAVAILABLEUNDERTHE)NDOORUNIT
s 4HEPROJECTIONOF)NDOORUNITMUSTHOOKTOTHEHANGER
$RAINHOSE
#ONNECTINGCORD
#ONNECTED
SECTION
)NSULATIONMATERIALFORPIPE
CONNECTION
3LEEVEOF
PROTECTIONPIPE
0ULLTHISTOTHEFRONTDURINGTHE
CONNECTIONOFREFRIGERATING
PIPETOEASETASK
#ONNECTING
CORD
2EFRIGERATING
PIPE
7ALLHOLE
$RAINHOSE
$RAINLAYOUTOFBACKWARDPIPINGFROMLEFT
0IPE
#ABLE
(EAT
INSULATIONPIPE
3 Heat Insulation and Finish of the Piping
4 Installation of Drain Hose
s 4HECONNECTEDTERMINALSSHOULDBECOMPLETEDSEALED
WITHHEATINSULATORANDTHENTIEDUPWITHRUBBERSTRAP
s $ONOTTIETHETERMINALSWITHTHETAPETOOTIGHT
)FANYCLEARANCE OROVERTIGHTENINGMAYCAUSE
CONDENSATION
s 0LEASETIETHEPIPEANDPOWERLINETOGETHERWITHVINYL
TAPEASSHOWNINTHElGURESHOWINGTHEINSTALLATIONOF
)NDOORAND/UTDOORUNITS
s 4OENHANCETHEHEATINSULATIONANDTOPREVENTWATER
CONDENSATIONPLEASE COVERTHEOUTDOOR PART OFTHE
DRAINHOSEANDPIPEWITHINSULATIONPIPE
s #OMPLETELYSEALANYGAPWITHPUTTY
0UTTY
0UTTY
"ENDINGUPWARDS #ONDENSEDWATER
POND
#ONDENSEDWATER
POND
$ITCH
"ESURETHATTHEDRAINHOSEIS
NOTLOOSELYCONNECTEDBENDOR
PROPERCONDITIONLIKELEFTlGURE
9OUAREFREE TOCHOOSE THE SIDELEFT ORRIGHT FORTHE INSTALLATIONOF DRAIN
HOSE0LEASEENSURETHESMOOTHmOWOFCONDENSEDWATEROFTHE)NDOOR
UNITDURINGINSTALLATION#ARELESSMAYRESULTINWATERLEAKAGE
CAUTION
CAUTION
CAUTION
CAUTION

Other manuals for Hitachi RAK-35PSPA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAK-35PSPA and is the answer not in the manual?

Hitachi RAK-35PSPA Specifications

General IconGeneral
Capacity3.5 kW
Star Rating3 Star
Cooling Capacity3.5 kW
Outdoor Unit Noise Level52 dB
Indoor Unit Dimensions (WxHxD)800 x 290 x 200 mm
Indoor Unit Weight9 kg
TypeSplit Air Conditioner
Power Supply230 V, 50 Hz, 1 Phase
Outdoor Unit Dimensions (WxHxD)780 x 540 x 285 mm
Air Flow (Indoor Unit)600 m³/h
RefrigerantR-32