CONSTRUCTION AND DIMENSIONAL DIAGRAM
MODEL RAS-08LH2/10LH2/14LH2
RAS-08LH2(B)/10LH2(B)/14LH2(B)
Note:
1. Servicing space of 100mm or more is required on the left and right sides of the indoor unit and also 50mm
or more space is required above the unit
2. Insulated pipes should be used for both the narrow and wide dia. pipes.
3. Piping length is within 15m (RAS-14LH2/RAS-14LH2(B)), 10m (RAS-08LH2/RAS-08LH2(B)/RAS-10LH2/
RAS-10LH2(B))
4. Height different of the piping between the indoor unit and the outdoor unit should be within 5m.
5. Power supply cord length is about 2m
6. Connecting cable 2.5mm dia. x 3 (AB Line), 1.6mm dia. x 2 (CD Line) is used for the connection.