EasyManua.ls Logo

Hitachi RAS-14EH2 - Page 81

Hitachi RAS-14EH2
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
79
Communication error.
LD301 blinks 9 times.
Is the connecting cable
connected properly?
(Is 35V being output on the
indoor unit side?)
Are CN3 and CN4
connected?
Is DC35V being output
between terminals C and D?
Normal: DC32V 39V
Standby: DC18V 23V
Is DC35V being output at
both ends of R35?
Connect CN 3 and CN4.
Connect properly.
Replace the power P.W.B.
Defective SW power supply
Replace the power P.W.B.
NF coils, IF coils, etc.
may be broken.
Check the interface circuit
and replace the main
P.W.B. if needed.
Yes
Yes
Yes
Yes Yes
No
No
No
No
No
07K394_RAS-14EH2_061-082_E 2007.10.31, 16:4679

Related product manuals