HHAW
SERVICE MANUAL
TECHNICAL INFORMATION
REFER TO THE FOUNDATION MANUAL
ROOM AIR CONDITIONER
SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT.
FOR SERVICE PERSONNEL ONLY
3HS01-CAR / 3HS01-SAR
3HS41-CAR / 3HS41-SAR
3HS81-CAR / 3HS81-SAR
798
295
258
11
750 (+91)
548
288 (+42)
35
RAS-10SH3 RAC-10SH3
1ø, 220V, 50Hz
2.5 (1.6 - 3.1)
8,500 (5,400 - 10,540)
3.9
3.4 (1.7 - 4.2)
11,560 (5,780 - 14,280)
798
295
258
750 (+91)
548
288 (+42)
35
RAS-14SH3 RAC-14SH3
1ø, 220V, 50Hz
3.5 (1.6 - 3.8)
11,900 (5,440 - 12,920)
4.8
4.2 (1.7 - 5.2)
14,280 (5,780 - 17,680)
SPECIFICATIONS
SPECIFICATIONS‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥
HOW TO USE ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥
CONSTRUCTION AND DIMENSIONAL DIAGRAM‥‥‥‥
MAIN PARTS COMPONENT‥‥‥‥‥‥‥‥‥‥‥‥‥‥
WIRING DIAGRAM ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥
WIRING DIAGRAM OF THE PRINTED WIRING BOARD
‥‥‥
BLOCK DIAGRAM ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥
BASIC MODE ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥
REFRIGERATING CYCLE DIAGRAM ‥‥‥‥‥‥‥‥‥
DISASSEMBLY & ASSEMBLY PROCEDURE ‥‥‥‥‥‥
DESCRIPTION OF MAIN CIRCUIT OPERATION ‥‥‥‥
SERVICE CALL Q&A ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥
TROUBLE SHOOTING ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥
PARTS LIST AND DIAGRAM ‥‥‥‥‥‥‥‥‥‥‥‥
CONTENTS
INDOOR UNIT + OUTDOOR UNIT
4
5
56
58
61
65
66
141
After installation
DC INVERTER
COOLING
HEATING
TYPE
MODEL
POWER SOURCE
TOTAL INPUT
TOTAL AMPERES
CAPACITY
TOTAL INPUT
TOTAL AMPERES
CAPACITY
DIMENSIONS
NET WEIGHT
(mm)
(A)
(B.T.U./h)
W
H
D
(kg)
(kW)
(A)
(B.T.U./h)
(kW)
(W)
(W)
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
NO.0060E
600 (400 - 1,100)
3.2
780 (400 -1,100)
1,070 (400 - 1,300)
5.1
1,020 (400 -1,400)
11
MARCH 2012
RAS-10SH3
RAS-14SH3
RAS-18SH3
RAC-18SH3
PAM
RAC-10SH3
RAC-14SH3
798
295
258
792 (+91)
600
299 (+46)
41
RAS-18SH3 RAC-18SH3
1ø, 220V, 50Hz
5.2 (1.1 - 5.5)
17,680 (3,740 - 18,700)
7.62
6.2 (1.1 - 8.3)
21 080 (3,740 - 28 220)
INDOOR UNIT
OUTDOOR UNIT
1,600 (500 - 2,300)
7.4
1,660 (500 -2,700)
12
, ,
53
84
86
90
101
108

Questions and Answers

  • C
    Christopher WashingtonAug 8, 2025
    Why is my Hitachi RAS-14SH3 Air Conditioner filter cleaning not starting?
    • R
      Robert BrownAug 8, 2025
      The filter cleaning operation might not start due to several reasons. In basic cooling operation, it won't start even if you press the (MANUAL CLEAN) button. Also, it won't restart during or within 5 minutes after a cleaning operation to protect the device. Check if 'filter cleaning operation prohibited' is set and return to the filter cleaning operation setting. Ensure that the micro mesh stainless filter, dust catcher, filter cleaning wiper, and wiper cover are correctly installed. Lastly, filter cleaning is skipped if the unit is stopped by the Sleep Timer or Off Timer, but it will occur approximately once a week.
  • M
    Mitchell HarrisonAug 18, 2025
    What to do if my Hitachi RAS-14SH3 Air Conditioner cleaning unit stops halfway?
    • D
      dannymcbrideAug 18, 2025
      If the cleaning unit stops halfway, ensure that after filter cleaning wiper maintenance, the cleaning unit is returned to the right end part using the remote controller. Also, check if the micro mesh stainless filter, dust catcher, filter cleaning wiper, and wiper cover are correctly installed. The (CLEAN) indicator will light for 4 seconds and then turn off for 1 second if there is a problem.
  • A
    Alexandra MartinAug 28, 2025
    Why does my Hitachi RAS-14SH3 make noise during filter cleaning?
    • T
      Tommy SmithAug 28, 2025
      During the filter cleaning operation, several noises are normal. A whirring motor noise comes from the cleaning unit's motor. A clapping noise is generated when the dust catcher collects dust or when it's turned over by the cleaning unit. Also, a sweeping sound occurs when the cleaning unit sweeps the dust.

Hitachi RAS-14SH3 Specifications

General IconGeneral
BrandHitachi
ModelRAS-14SH3
CategoryAir Conditioner
LanguageEnglish

Related product manuals