– 5 –
SPECIFICATIONS
MODEL
FAN MOTOR
FAN MOTOR CAPACITOR
FAN MOTOR PROTECTOR
COMPRESSOR
COMPRESSOR MOTOR CAPACITOR
OVERLOAD PROTECTOR
OVERHEAT PROTECTOR
FUSE (MICRO COMPUTER CIRCUIT)
POWER RELAY
POWER SWITCH
TEMPORARY SWITCH
SERVICE SWITCH
TRANSFORMER
VARISTOR
NOISE SUPPRESSOR
THERMOSTAT
REMOTE CONTROL SWITCH (LIQUID CRYSTAL)
FUSE CAPACITY
RAS-24CH7
20 W
NO
NO
NO
NO
NO
3.15A
G4A
YES
NO
YES
NO
450NR
NO
YES(IC)
YES
RAC-24CH7
40 W
2.5 F,450V
YES (INTERNAL)
SHV33YC6-U
50 F, 450VAC
YES (INTERNAL)
YES (INTERNAL)
NO
NO
NO
NO
NO
NO
NO
NO
YES(IC)
NO
30 A TIME DELAY FUSE
---------- 1700gUNIT
REFRIGERANT CHARGING
VOLUME
(Refrigerant R22)
ADDITIONAL REFRIGERANT R22
AT 25g PER EVERY METER IF
PIPE LENGTH MORE THAN 8m
PIPES (MAX. 15m)