– 65 –
10. Outdoor DC Fan Motor control circuit
This model uses DC Fan Motor which has a controller circuit built in the Motor.
This DC Fan Motor will rotate by control voltage apply to Vsp input. (Voltage range: 1.7 to 7V DC)
Motor will output FG pulse by following this motor revolution.
indoor microcomputer.
This PWM control signal will convert to Vsp voltage by smoothing circuit (R242 & C209)
rotation speed.
DC Fan Motor circuit has to match the Fan Motor revolution with instructed revolution. Such as...
FG feedback: Faster Instruction: Slower ... Decrease pulse width
FG feedback: Slower Instruction: Faster ... Increase pulse width
FG pulse is also used for Fan Motor failure detection.
Microcomputer will monitor FG pulse 30 seconds after start the fan motor. If there is no signal detected,
it will consider that the Fan Motor was malfunction and stop the operation. In this case, LD302 on control
R107 and IC4 are used for Fan Motor over current.
Vsp high : Faster ;
Vsp low : slower ;
Vsp lower than 1.7V : stop
P.W.B. will blink 12 times. (Fan Motor lock detected)
FG pulse will feed back to Outdoor microcomputer
15
.
Outdoor microcomputer will output PWM control signal from
75
by following the instruction from
Fan motor will start to rotate when Vsp was proceeding over than 1.7V, and generate FG pulse by