– 25 –
MAINTENANCE
Cleaning and maintenance must be carried out only by quali ed service
personnel. Before cleaning, stop operation and switch off the power supply.
1. PRE-FILTER
Clean the pre- lter, as it removes dust inside the room. In case the pre- lter is full of dust, the air
ow will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to
clean the pre- lter following the procedure below.
CAUTION
1
Open the front panel and remove the pre- lter
Gently lift and remove the air purifying lter
from the pre- lter frame.
2
Vacuum dust from the pre-filter and air
purifying lter using vacuum cleaner. If there is
too much dust, pre- lter only rinse under running
tap water and gently brush it with soft bristle
brush. Allow pre- lters to dry in shade.
3
Re-insert the air purifying lter to the lter
frame. Set the lter with “FRONT” mark facing
front, and slot them into the original state.
After attaching the pre- lters, push the front
panel at three arrow portions as shown in
gure and close it.
CAUTION
Do not wash with hot water at more than 40°C. The pre- lter may shrink.
When washing it, shake off moisture completely and dry it in the shade; do not expose it directly
to the sun. The pre- lter may shrink.
Do not use detergent on the air purifying lter as some detergent may deteriorate the lter electrostatic
performance.
!
!