1.33˚C.
SFTDSW
0.66
˚C.
Fan speed set to "auto"
1 min.
Basic Heating Operation
Start
Stop Stop StopStart Start
Thermo
OFF
Thermo
OFF
Heating set temperature 
(remote control set temperature
(+))
Start/stop button
Thermo judgment
Indoor fan
Ultra-Hi
Hi
Med
Lo
Ultra-Lo
Operation lamp
Max.
Rating
    3000
0
Compressor  speed
Outdoor fan
Reversing valve (cooling "on" model)
Ther
mo OFF
Dash period
TWMAX
Wtd
Defrost signal
Preheating judgment
30sec. 30sec.
10sec.
15sec. 15sec.
15sec. 15sec. 15sec.
10sec.
15sec.
15sec.
3min.
Max. 3 min.
Preheating released
Control by
heat exchanger temper
ature
Control by
heat exchanger temperature
15sec.
Control by
heat exchanger temper
ature
Control by
heat exchanger temper
ature
Control by
heat exchanger temper
ature
18˚C
10sec.
30sec
. 30sec.
10sec.
30sec
. 30sec.30sec. 30sec. 30sec. 30sec.
10sec.
Preheat released
WMIN
(WSTD)
(WMAX)
NOTE (10)
WMAX2
Notes:
(1) Condition for entering into Hot Dashed mode. When fan set to “Hi” or “Auto mode” and i) Indoor temperature is lower than 18°C, and ii) outdoor temperature is lower than 10°C,
and  iii)  Temperature  difference  between  indoor  temperature  and  set  temperature  has  a  corresponding  compressor  rpm  (calculated  value  in  Table  3)  larger  than  WMAX.
(2) Hot Dashed  will  release  when  i)  Room  temperature  has  achieved  the  set  temperature  +  SFTDSW.  ii)  Thermo  off.
(3) During Hot  Dashed  operation,  thermo  off  temperature  is  set  temperature  (with  shift  value)  +3°C. After  thermo  off,  operation  continue  in  Fuzzy  control  mode.
(4) Compressor minimum  “ON”  time  and  “OFF”  time  is  3  minutes.
(5) During normal heating mode, compressor maximum rpm WMAX will maintain for 120 minutes if indoor temperature is higher than 18°C. No time limit constrain if outdoor temperature is 
  lower  than  4°C.
(6) During Hotkeep  or  Defrost  mode,  indoor  operation  lamp  will  blink  at  interval  of  0.5  seconds “ON”  and  0.5  second  “OFF”.
(7) When heating  mode  starts,  it  will  enter  into  Hotkeep  mode  if  indoor  heat  exchanger  temperature  is  lower  than  YNEOF  +  0.33°C.
(8) When fan  is  set  to  “Lo”, compressor  rpm  will  be  limited  to  WBEMAX.    When  fan  is  set  to  "Med",  compressor  rpm  will  be  limited  to  WJKMAX.
(9) In 
“Ultra-Lo”  fan  mode,  if  indoor  temperature  is  lower  than  18°C, indoor  fan will  stop.  If  indoor  temperature is  higher  than  18°C +  0.33°C, fan  will  continue  in  “Ultra-Lo”  mode.
During  Hotkeep  or  Defrost  mode,  fan  will  continue  in  “Ultra-Lo”  mode.
(10) During  Hot  Dashed,  when  room  temperature  reaches  set  temperature  +  SFTDSW  compressor  rpm  is  actual  rpm  x  DWNRATEW.
Temperature
Calculated
differenc
e
compressor  rpm
1.66°C
2200 min
–1
2.00°C2600 min
–1
2.33°C3000 min
–1
2.66°C3400  min
–1
3.00°C3800 min
–1
3.33°C4200 min
–1
Table 3  Compressor rpm
Notes
:
1. See the data in Table 1-Table 2 on
page 47 & 49 for each constant in
capital  letters  in  the  diagrams.
(with  shift  value)