Hitachi RAS-E10H2 - Reversing Valve Control Circuit Details

Hitachi RAS-E10H2
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Main P.W.B.
HIC
O.H. thermistor
DEF. thermistor
Outdoor temperature
thermistor
Microcomputer
AX-8V10
OH
DEF
Outdoor
temperature
59
63
64
0V
0V
0V
C302
0V
R303
R306
0V
R302
R305
C303
C304
R304
R301
0V
CN8
CN9
+5V
+5V
+5V
CN10
1
2
1
2
1
2
20
21
22
Fig. 6-12
R303 Voltage (V)
Table 6-2
1
CN2
3
2
D701
32
29
C
35V
D
0V
12V
16
1
C2
6-5. Reversing valve control circuit
In this unit, reversing valve control circuit turns ON/OFF the power to the reversing valve coil by
opening/closing the reversing valve relay
.
Opening/closing of relay will differ depending on the operation condition. (In the cooling cycle,
reversing valve relay is normally ON (close).)
Table 6-3 shows the circuit operation of each operation mode. If the following result is not obtained,
reversing valve control circuit may be defective.
Table 6-3
Point
Operation mode
Cooling
In normal cooling operation
In normal heating operation
In defrosting operation
approx. 35 V
approx. 35 V
0VHi
0VHi
12VLo 0V (not fixed)
Heating
Between Pin 29
of microcomputer and 0V
Between Pin 32 of HIC
and 0V
Between 1 and 3 CN2
Main P.W.B.
Reversing
valve
Reversing valve
relay coil
(RL5)
HIC
Fig. 6-13
Microcomputer
Reversing valve relay
RL5
- 63
-