AUTO FRESH DEFROSTING
AUTO OPERATION
NICE TEMPERATURE RESERVATION
INFRARED REMOTE CONTROL
After the ON/OFF button is pressed
to stop heating, the outdoor unit is
still working with the OPERATION
lamp lighting.
Fan speed does not change when
fan speed selector is changed
during auto operation.
When on-timer has been
programmed, operation starts befor
e
the preset time has been reached.
Does Nice temperature reservation
function operate during dehumidifying?
Even if the same time is preset,
the operation start time varies.
Timer cannot be set.
The current time display
disappears soon.
The timer has been programmed,
but the preset time disappears.
Auto Fresh Defrosting is carried out : th
e
system checks the outdoor heat exchanger
and defrosts it as necessary before stopping
operation.
At this point fan speed is automatic
.
This is because Nice temperature reservatio
n
function is operating. This function starts
operation earlier so the preset temperature is
reached at the preset time. Operation may start
maximum 60 minutes before the preset time.
It does not work. It works only during coolin
g
and heating.
This is because Nice temperature reservatio
n
function is operating. The start time varie
s
according to the load of room. Since load varie
s
greatly during heating, the operation start time is
corrected, so it will vary each day
.
Has the clock been set?
Timer cannot be set
unless the clock has been set.
The current time disappears
in approx. 10 seconds. The
time set display has priority
.
Is the current time past the preset time?
When the preset time reaches the current
time, it disappears.
When the current time is
set the display flashes for
approx 3 minutes
.
Q8
A8
Q9
A9
Q10
A10
Q11
A11
A1
2
Q13
A1
3
Q14
A14
Q15
A1
5
Q1
2
OTHERS
Q18
A1
8
Q19
A1
9
Q20
A2
0
Q21
A2
1
Q22
A2
2
The indoor fan varies among
high air flow, low air flow and
breeze in the auto fan speed
mode. (Heating operation)
This is because the cool
wind prevention functio
n
is operating, and does
not indicate a fault.
The heat exchanger temperatur
e
is sensed in the auto speed mode.
When the temperature is low, th
e
fan speed varies among high ai
r
flow, low air flow and breeze.
Loud noise from the outdoor unit is
When the “Sleep” timer is set during
operation,
(1) The indoor fan won’t rotate
.
(No air comes from the unit)
(2) The air speed won’t change.
The preset temperature is not
indicated on the remote control.
(1) The temperature arrives at the preset indoor
temperature and the air conditioner unit is
temporarily stopped. Within about 3 minutes,
the fan starts rotation.
(2) When the unit operates at “LOW” air speed,
it continues to operate at the same speed.
When automatic operation is performed, the
preset temperature won’t be indicated.
However, you can adjust the temperature within
a range of ±3°C by pressing the “Room
Temperature” button.
If the temperature is 1°C higher than the auto
preset temperature, 1°C will appear.
If the temperature is 1°C lower than the auto
preset temperature, 1°C will appear
.
heard when operation is started.
When operation is started, the compressor
rotation speed goes to maximum to increase th
e
heating or cooling capability, so noise becomes
slightly louder. This does not indicate a fault.
Noise from the outdoor uni
t
occasionally changes.
The compressor rotation speed changes according to
the difference between the thermostat set temperature
and room temperature. This does not indicate a fault.
There is a difference between the set
temperature and room temperature.
There may be a difference between the set
temperature and room temperature because of
construction of room, air current, etc. Set th
e
temperature at a comfortable for the space.
Air does not flow immediatel
y
after operation is started.
Preliminary operation is performed for one
minute when the power switch on and heatin
g
or dehumidifying is set. The operation lamp
blinks during this time for heating. This does
not indicate a fault.