LD301 blinks 12 times.
Fan lock error
.
Is CN24 connected?
Is the propeller fan
locked?
Have the 1A fuse and
R107 blown?
Is +15V being generated?
Check voltage both between
CN18 3 and 6 on the main
P.
W.B., and between +15V
and 15-0V (silk-screened) on
the main P.W.B.
Is the fan operating?
(An error occurs after the
fan operates for 2 minutes.)
Is the voltage between 4
and 6 at CN24 normal
?
(Normally, the voltage is
above approx. DC1.7V.)
Connect the connector.
Remove any
obstructions.
Replace the fan motor
and main P.W.
B.
Is the voltage between 4 and
7 at CN24 normal
?
Check to see if the voltage is
within 2.5V
±
0.5V using a
tester
.
(In effect, the output voltage
is alternately switched
between 5V and 0V.)
Replace the main
P.W.
B.
Replace the fan motor.
Yes
No
No
No
Ye
s
No
No
No
No
No
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
※
LD 301 blinks 10 times.
Defective power supply
voltage
Is AC220-230V being output
at terminals A and B on
the terminal board?
Apply AC220-230V.
Check the interior wiring.
TAB05, TAB11, reactor,
and C023 (yellow green)
connected properly?
Connect properly.
Replace the main P.W.B.
Possible causes include:
Power relay malfunction
Defective microcomputer
terminal
Yes
Ye
s
Ye
s
No
No
No
※
- 84
-