EasyManua.ls Logo

Hitachi RAS-E10H2 - POWER MODULE DIAGNOSIS WITH MULTIMETER

Hitachi RAS-E10H2
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
See next page
for measuring
value usin
g
multimeter
PS21564-C
Circuit of 1 device
Gate
Collector
Emitter
Internal circuit
diagram of
module
Terminal
symbols of
power module
6PGU
12PGV
18PGW
21NGU
22NGV
23NGW
24Fail signal
31P
32U
33V
34W
35N
28 26 24 22 20 18 16 12 10 6 4 1
27 25
35 34 33 32 31
N W V U
P
23 21 15 13 9 7 3
Model
PUV
W
U
PN
V
W
N
Diagnosis procedure for power module using multimeter
[Inverter section]
Set the multimeter to resistance range of ×
100. If ×100 is not provided, measure with the range of ×
1 to × 100.
If the pointer does not swing when the following continuity check is performed, it is normal.
(When a digital multimeter is used, + and - terminals will be reversed, since the orientation of built-in
battery is inverted.)
Note:
If internal circuit of power module is disconnected (open) and pointer of the mutimeter does not swing,
it may be assumed to be normal. If the pointer swings when + and - terminals are connected in
reverse, it is normal. Compare swing statuses for U, V and W phases: If the statuses at all 3 points are
the same, it is normal.
- 93
-