EasyManua.ls Logo

Hitachi RCIM-1.5FSN3 User Manual

Hitachi RCIM-1.5FSN3
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SET FREE SERIES
FSXN1E
FSXNH(E)
INSTALLATION AND OPERATION MANUAL
MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO
INSTALLATIONS- UND BETRIEBSHANDBUCH
MANUEL D’INSTALLATION ET DE FONCTIONNEMENT
MANUALE D’INSTALLAZIONE E D’USO
MANUAL DE INSTALAÇÃO E DE FUNCIONAMENTO
INSTALLATIONS- OG BETJENINGSVEJLEDNING
INSTALLATIE- EN BEDIENINGSHANDLEIDING
INSTALLATION- OCH DRIFTHANDBOK
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ ΚΑΙ ΛΕΙΤΟΥΡΓΙΑΣ
PMML0294A_rev.2_02-2014.indb 1 14/07/2014 12:27:46
Question and Answer IconNeed help?

Do you have a question about the Hitachi RCIM-1.5FSN3 and is the answer not in the manual?

Hitachi RCIM-1.5FSN3 Specifications

General IconGeneral
BrandHitachi
ModelRCIM-1.5FSN3
CategoryAir Conditioner
LanguageEnglish

Summary

SAFETY PRECAUTIONS

Symbols used

Explanation of warning symbols like DANGER, CAUTION, NOTE.

Additional safety information

Further safety instructions, including pressure vessel specifics.

Pressure vessel and safety device safety

Safety aspects related to pressure components and switches.

AUTOMATIC CONTROLS

REFRIGERANT CYCLE DIAGRAMS

UNIT TRANSPORT AND HANDLING

Outdoor Unit Transport

Guidelines for securely fastening units during transport.

Lifting Methods

Instructions for proper lifting techniques using slings.

CENTER OF GRAVITY INFORMATION

UNIT INSTALLATION GUIDELINES

Outdoor Unit Positioning Conditions

Criteria for selecting an installation location for outdoor units.

Installation Space Requirements

Specifications for clearance around outdoor units.

FOUNDATION AND ANCHORAGE

PIPING WORK AND REFRIGERANT CHARGE

Refrigerant Pipe Selection

Guidelines for choosing correct pipe sizes and kits.

ADDITIONAL REFRIGERANT CHARGE

Air-Tight Test Procedure

Steps and precautions for performing an air-tight test.

Refrigerant Charge Calculation

Methods for calculating additional refrigerant needed.

Charging Work Steps

Procedures for charging refrigerant into the system.

Refrigerant Amount Judgement System

Automatic system for checking refrigerant levels.

Refrigerant Gas Leakage Precautions

Safety measures and concentration limits for gas leaks.

ELECTRICAL WIRING

Cable Size Specifications

Wire size recommendations for power and transmission cables.

Outdoor Unit Wiring Instructions

Specific wiring connections for outdoor units.

DSW SWITCH SETTINGS

DSW Switch Settings on PCB1

Configuration of DIP switches on the PCB.

FUNCTION SETTING PROCEDURES

TEST RUN PROCEDURES

Preliminary Test Run Checks

Essential checks before performing the test run.

TEST RUN CHECK LIST

Test Run Check List

A checklist to verify test run completion and system status.

ALARM CODES

Most common alarm codes

List and explanation of common error codes and their causes.

CONTROL AND SAFETY DEVICES

Compressor protection

Details on devices protecting the compressor.

Related product manuals