ENGLISH
16 ELECTRICAL WIRING
16.1 GENERAL INFORMATION
D A N G E R
• Turn off the main power switch to the indoor unit and the
outdoor unit before electrical wiring work or a periodical check
is performed.
• Check to ensure that the indoor fan and the outdoor fan have
stopped before electrical wiring work or a periodical check is
performed.
• Protect the wires, drain pipe, electrical parts, etc. from rats
or other small animals. If not protected, rats may gnaw at
XQSURWHFWHGSDUWVDQGDWWKHZRUVWD¿UHZLOORFFXU
• Electrical wiring work must be performed by authorized
LQVWDOOHUV ,QFRUUHFW LQVWDOODWLRQ E\ D QRQDXWKRUL]HG LQVWDOOHU
PD\FDXVHDQHOHFWULFVKRFNRUD¿UH
• Perform electrical work according to this Installation Manual and
all the relevant regulations and standards. Failing to follow these
instructions can cause capacity shortage and performance
GHJUDGDWLRQUHVXOWLQJLQDQHOHFWULFVKRFNDQGD¿UH
• 8VHVSHFL¿HGFDEOHVEHWZHHQXQLWV6HOHFWLQJLQFRUUHFWFDEOHV
PD\FDXVHDQHOHFWULFVKRFNRUD¿UH
• Tighten screws according to the following torque:
01P
0WR1P
C A U T I O N
• 8VHWZLVWHGVKLHOGHGSDLUFDEOHRUVKLHOGSDLUFDEOHIRUWUDQVPLVVLRQ
ZLUHVEHWZHHQWKHLQGRRUDQGWKHRXWGRRUXQLWVIRUWKHFRQWUROFDEOH
EHWZHHQLQGRRUXQLWVDQGIRUWKHFDEOHRIUHPRWHFRQWUROVZLWFKDQG
FRQQHFWWKHVKLHOGHGSDUWWRWKHHDUWKVFUHZLQWKHHOHFWULFDOER[RI
WKHLQGRRUXQLW
• :UDS WKH ¿HOG VXSSOLHG LQVXODWLRQ DURXQG WKH ZLUHV DQG SOXJ WKH
ZLULQJFRQQHFWLRQKROHZLWKWKHVHDOPDWHULDOWRSURWHFWWKHSURGXFW
IURPDQ\FRQGHQVDWHZDWHURULQVHFWV
• 7LJKWO\VHFXUHWKHZLUHVZLWKWKHFRUGFODPSQHDUWKHHOHFWULFDOER[
• /HDG WKHZLUHV WKURXJK WKH NQRFNRXW KROH LQ WKH VLGH FRYHUZKHQ
XVLQJFRQGXLW
• 6HFXUHWKHFDEOHRIWKHUHPRWHFRQWUROVZLWFKXVLQJWKHFRUGFODPS
LQVLGHWKHHOHFWULFDOER[
*HQHUDOFKHFN
1 0DNHVXUHWKDWWKH¿HOGVHOHFWHGHOHFWULFDOFRPSRQHQWV
(main power switches, circuit breakers, wires, conduit
connectors and wire terminals) have been properly selected.
Make sure that the components comply with National
Electrical Code (NEC).
2 Check to ensure that the power supply voltage is within
RIWKHUDWHGYROWDJH
3 Check the capacity of the electrical wires. If the power
source capacity is too low, the system cannot be started due
to the voltage drop.
4 Check to ensure that the ground wire is connected.
16.2 ELECTRICAL WIRING CONNECTION FOR INDOOR UNIT
1 The electrical wiring connection for the indoor unit is shown
below.
(OHFWULFDOER[
Remote control switch cable
Control cable
Power source cable
Indoor unit
Air panel
Cable for auto swing motor
Wire clamp
N O T E
)L[WKHZLUHVZLWKWKH FRUG FODPSV %H FDUHIXO WKDW WKH ZLUHV GRHV QRW
FRQWDFWWKHHGJHVRIWKHFRYHUIRUWKHHOHFWULFDOFRPSRQHQWV
2 When installing the optional air panel, connect the connector
for the auto swing motor and the connector for the indoor
unit. Refer to the section
,QVWDOODWLRQRIRSWLRQDODLU
SDQHO3$31$0 for details.
ON
1 2
A B 1 2
Remote control switch cable
Control cable (Outdoor unit to indoor
unit and indoor unit to indoor unit)
Terminal block
(OHFWULFDOER[
Wire clamp
Air panel
Indoor unit
Connector (CN17)
Earth screw
Control cable
Remote control
switch cable
Power source
cable
PCB
Cable for auto swing motor
N O T E
)L[WKHZLUHVE\ZLUHFODPS%HFDUHIXOWKDWWKHZLUHVGRHVQRWFRQWDFW
WKH HGJHV RI WKH FRYHUIRU WKH HOHFWULFDOFRPSRQHQWV WKHHGJHV RIWKH
VXVSHQVLRQEUDFNHWDQGGUDLQSLSH
Electrical wiring
PMML0363A rev.2 - 08/2016 - P541655927