Hitachi America, Ltd. RCU SERIES
`
4.5 I/O Power line and Connection of Fuse
For power lines, use copper wire rated 600V, +75ºC. Wire gauge and fuse capacity must be
sized based on rated output current of RCU. Please refer to Table 4.2 for the minimum size
of power lines (copper) and following fuse capacity. When three or more parallel wires are
used, please pay attention to avoid overloading.
Table 4.2 Wire, according to capacity and Fuse recommendation
1) Use copper wire rated for 600V, 75ºC.
2) Use only fast-blow fuses.
Call 1(800)985-6929 for Sales
Call 1(800)985-6929 for Sales