Alarm     
Code
Retry 
Stop 
Code
Yutaki 
S/SC
Yutaki 
S80
Yutaki 
M
Origin Detail of Abnormality Main Factors
75 - o o o Indoor
Freeze Protection by Cold water 
inlet, outlet temperature detection
76 - o o o Indoor
Freeze Protection Stop by indoor 
liquid temperature thermistor 
77 - o o o Indoor-LCD Receiver  Communication failure
No Opentherm/Hlink 
communication for a continuous 
period of 10 minutes.
78 o o o Indoor-LCD RF Communication failure
There is no communication for 1 
hour with on or two RF receives 
which are bound to the RF-Bridge.
79 - o o o Indoor -outdoor Unit Capacity setting Error
There is no concordance between 
indoor outdoor unit capacity 
80 - o o o
Indoor LCD H-link  RCS transmission error No H-link communication for a 
continuous period of 1 minute 
between Indoor and LCD User 
control by connection wiring 
(breaking, wiring error, etc.)
LCD (if no H-LINK RCS has no power)
81 o o o Indoor
“Momentary Power interruption” or 
“Low voltage detected”
101 - o - Indoor Activation of high pressure switch
102 P12 - o - Indoor
Activation of protection control for 
excessively high pressure
Stop after P12 retry due to 
discharge pressure Pd ≥ 2.78 MPa 
continued for 10 seconds.
104 P06 - o - Indoor Activation of low control
Stop after P06  retry due to Ps ≤ 
0.15 MPa continued for 90 seconds
104 P06 - o - Indoor Activation of low control Immediate stop with Ps ≤ 0.1 MPa 
105 P11 - o - Indoor Excessively low pressure difference
Stop after P11 retry due to pressure 
ratio ε < 1.8 continued for 3 
minutes.
106 - o - Indoor
Excessively high discharge gas 
temperature
Td ≥ 120 ºC continued for 10 
minutes, Td ≥ 140 ºC continued for 
5 seconds
129 - o - Indoor
Failure of discharge gas pressure 
sensor
Loose, disconnected, broken or 
short-circuited connector
130 - o - Indoor
Failure of suction gas pressure 
sensor
Loose, disconnected, broken or 
short-circuited connector
132 - o - Indoor
Transmission error between 
Inverter PCB and Main PCB
Described in inverter abnormal stop 
control
134 - o - Indoor
Abnormality of Power Supply 
Phase
Reverse/Open Phase
135 - o - Indoor Incorrect PCB Setting
Wrong DSW setting in the case of 
Co041
151 - o - Indoor
Excessively low voltage or 
excessively high voltage for the 
inverter
Described in inverter abnormal stop 
control
152 - o - Indoor
Abnormal operation of the current 
sensor
Described in inverter abnormal stop 
control
153 - o - Indoor
Activation of protection for inverter 
instantaneous over current
Described in inverter abnormal stop 
control
154 - o - Indoor
Transistor module protection 
activation
Described in inverter abnormal stop 
control
155 - o - Indoor
Increase in the inverter n 
temperature or abnormality 
Described in inverter abnormal stop 
control
156 - o - Indoor Inverter non operation
Described in inverter abnormal stop 
control
157 - o - Indoor
Inverter Communication 
abnormality
Described in inverter abnormal stop 
control
TROUBLESHOOTING
PMML0335A rev.1 - 04/2016
172