Please read the following instruction carefully in order to make sure that the heater is used
properly and does not cause malfunction.
1. Use
HP-115 and HP-125 universal oil heater are suitable for heating big size buildings without
central heating (shops, service stations, industrial buildings, warehouses, inventory buildings,
basements, garages, etc.) The heater runs on most oils of mineral and plant origin, such as motor
oils, heating oil, gear oils, hydraulic oils, HBO I, II, III oils with maximum kinematic viscosity
6.00 mm²/s at a temperature of 20ºC and maximum ignition temperature not lower than40ºC and
density above 0.94 g/cm³.
In light of binding regulations in Poland it is recommended that diesel oil, heating oil or
biodiesel be used.
NOT TO BE USED WITH TRANSFORMER (INSULATING) OILS
THEY MAY CONTAIN SUBSTANCES THAT CAN DAMAGE THE HEATER
2. Storage conditions:
HP-115 and HP-125 universal oil heaters should be stored in the following conditions:
• temperature
-20-85°C
• relative humidity
5-85%
• pressure
800-1200hPa
• free of dust
• free of chemical pollutants.
3. Conditions for use:
HP-115 and HP-125 universal oil heaters should be operated under the following conditions:
• temperature
0-30°C
• relative humidity
5-85%
• pressure
800-1200hPa
environmental impact protection
IP20
• appropriate ventilation of heated area
4. Characteristics of the control panel:
the heater may be regulated and set at 15 and 22kW (HP-115) or 22 and 30 kW (HP-125),
protection against overheating the burner,
protection against overflow of oil in the burner,
automatic retaining of previous settings in case of power failure,
5. Safety measures:
HP-115/HP-125 universal oil heater is connected to 230V/50Hz alternating current network. A
fuse element (1A, 250V) was installed in the casing of the control panel. The fuse should always
be replaced with the power (230V/50Hz) switched off.
HP-115 /HP-125 universal oil heater is equipped with two bimetallic sensors assuring safe and
effective functioning of the device.

Related product manuals