EasyManua.ls Logo

HNC HV10-R75G1-2 User Manual

Default Icon
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HV10 Series Frequency Inverter
User Manual
HNC Electric Limited
Question and Answer IconNeed help?

Do you have a question about the HNC HV10-R75G1-2 and is the answer not in the manual?

HNC HV10-R75G1-2 Specifications

General IconGeneral
Efficiency≥96%
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit, Phase Loss, Ground Fault
Cooling MethodForced Air Cooling
Operating Temperature-10°C ~ +40°C (Derating above 40°C)
Storage Temperature-20°C ~ +60°C
Humidity5% ~ 95% RH, Non-condensing
Dimensions280mm x 400mm x 250mm
Weight18kg

Summary

Technical Specifications of HV10 Series Frequency Inverter

Input and Output Electrical Specifications

Details on rated voltage, frequency, allowable voltage variation, and overload capacity.

Control Characteristics and Typical Functions

Covers control modes, frequency settings, V/F curves, PID, RS485, and signal outputs.

Environmental and Structural Specifications

Includes DC brake, noise, operating status, display, alarms, environmental conditions, and cooling.

Inverter Installation and Wiring Guide

Installation Safety Precautions

Critical safety guidelines for installation, including power, grounding, and terminal handling.

Outline Drawings and Dimensions

Visual representation of the inverter's physical dimensions and keypad base.

Wiring Procedures and Considerations

Details on basic wiring, terminal functions, and essential wiring practices.

Communication Protocol Details

RTU Mode and Data Format

Explains Modbus RTU communication settings, frame structure, and data representation.

Register Map and Function Codes

Defines register addresses and function codes for reading and writing parameters.

Communication Parameter Descriptions

Details parameter addresses, data meaning, and R/W attributes for communication.

Exceptions and Handling

Troubleshooting Common Faults

Lists common abnormal phenomena and their corresponding possible causes and countermeasures.

Parameters Instructions Overview

Parameter Group Overview

Introduces parameter groups (00-08) and notes on modification rules.

Detailed Parameter Descriptions

Basic Operating Parameters (00 Group)

Details foundational parameters for motor control, frequency sources, and operation modes.

Auxiliary Operating Parameters (01 Group)

Covers parameters for starting, braking, jog operations, and multi-speed settings.

Analog/Digital I/O and PID Parameters

Configuration for I/O signals and PID control loops.

Advanced, Protective, and Communication Parameters

Settings for motor, protection, communication, and advanced functions.

Supplementary and Monitoring Parameters

Parameters for timing, counting, swing frequency, and system monitoring.