Steps for removing shipping restraints and preparing the scale for operation.
Instructions for adjusting the scale's feet to ensure it is perfectly level.
Adjusting the dashpot for optimal chart movement speed and settling time.
Ensuring the indicator tape correctly aligns with the zero line on the chart.
Calibrating the scale to accurately display the maximum weight capacity.
Positioning the indicator wire for clear visibility and proper zero alignment.
Adjusting the screw to set the weight threshold for activating the lights.
Guide for safely replacing burnt-out light bulbs in the scale.
Instructions for refilling the dashpot with the specified type of oil.
Correcting zero indication errors as detailed in setting-up instructions.
Fine-tuning the scale for correct maximum weight reading.
Correcting errors at 1/4, 1/2, or 3/4 capacity using chart balance weights.
Adjusting for zero indication when using non-standard platform attachments.