STORAGE INSTRUCTIONS
TROUBLESHOOTING
FREQUENTLY ASKED QUESTIONS
WARRANTY INFORMATION
© 2019 Sunbeam Products, Inc. All Rights Reserved. Distributed by Sunbeam Products, Inc., Boca Raton, Florida 33431.
1 YEAR LIMITED WARRANTY
Sunbeam Products, Inc. (“Sunbeam”) or if in Canada, Newell Brands Canada ULC (“NBC”) warrants that for a period
of one year from the date of purchase, this product will be free from defects in material and workmanship. Sunbeam
(or NBC), at its option, will repair or replace this product or any component of the product found to be defective
during the warranty period. Replacement will be made with a new or remanufactured product or component. If the
product is no longer available, replacement may be made with a similar product of equal or greater value. This is your
exclusive warranty. Do NOT attempt to repair or adjust any electrical or mechanical functions on this product. Doing so
will void this warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable.
Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. Sunbeam (or NBC)
dealers, service centers, or retail stores selling Sunbeam (or NBC) products do not have the right to alter, modify or
any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or
misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly,
repair or alteration by anyone other than Sunbeam (or NBC) or an authorized Sunbeam (or NBC) service center.
Further, the warranty does not cover: Acts of God, such as fire, flood, hurricanes and tornadoes.
What are the limits on Sunbeam’s (or NBC’s) Liability?
Sunbeam (or NBC) shall not be liable for any incidental or consequential damages caused by the breach of any
express, implied or statutory warranty or condition.
Except to the extent prohibited by applicable law, any implied warranty or condition of merchantability or fitness for a
particular purpose is limited in duration to the duration of the above warranty. Sunbeam (or NBC) disclaims all other
warranties, conditions or representations, express, implied, statutory or otherwise. Sunbeam (or NBC) shall not be
liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use the product
including incidental, special, consequential or similar damages or loss of profits, or for any breach of contract,
fundamental or otherwise, or for any claim brought against purchaser by any other party. Some provinces, states or
jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long
an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific
legal rights, and you may also have other rights that vary from province to province, state to state or jurisdiction to
jurisdiction.
How to Obtain Warranty Service
In the U.S.A.
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website at
www.holmesproducts.com.
In Canada
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website at
www.holmesproducts.com.
In the U.S.A., this warranty is offered by Sunbeam Products, Inc. located in Boca Raton, Florida 33431. In Canada, this
warranty is offered by Newell Brands Canada ULC, located at 20 B Hereford Street, Brampton, Ontario L6Y 0M1. If
you have any other problem or claim in connection with this product, please write our Consumer Service Department.
PLEASE DO NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF
PURCHASE.
FREQUENTLY ASKED QUESTIONS
Question Answer
What are the variables that affect
run time?
The estimated run time for this humidifier is based on average room
conditions. The actual run time of your humidifier is dependent on numerous
variables such as:
Air exchange in the room where the humidifier is placed.
Room construction of the room where the humidifier is placed.
Temperature of the room where the humidifier is placed.
Humidity levels in the room where the humidifier is placed.
Movement of occupants and the opening and closing of doors in the room
where the humidifier is placed.
Home furnishings in the room where the humidifier is placed.
How do I remove film on water
tank?
See Daily Maintenance instructions. Regular cleaning is recommended.
How can I extend the run time?
Run your unit on the lowest setting.
If your unit has electronics, set it to your desired humidity level. The unit
will turn on and off, which will extend the run time.
Fill the tank all the way full, place it on the base, let the water empty into
the base until it stops bubbling, then refill the tank full again. This ensures
maximum water capacity and will extend run time.
TROUBLESHOOTING
TROUBLE PROBABLE CAUSE SOLUTION
Unit does not turn on. * Not plugged in.
* Outlet not functioning.
4 Plug in unit.
4 Have outlet replaced by a licensed electrician.
Mist output minimal to
none.
* Filter has not absorbed water.
* Cool mist is invisible.
4 Wait 30 minutes for filter to absorb water.
4 Operate in High (II) setting.
Filter turns brown. * The filter has absorbed
minerals.
4 Replace your filter (HWF62) by calling
1-800-546-5637, or visiting
www.holmesproducts.com
.
P.N. 198538 HCM1100_19ESM1 Impreso en China
GCDS-HOL556120-SL
INFORMACION DE LA GARANTIA
DIAGNÓSTICO DE PROBLEMAS
PREGUNTAS FRECUENTES
INFORMACION DE LA GARANTIA
© 2019 Sunbeam Products, Inc. Todos los derechos reservados. Distribuido por Sunbeam Products, Inc., Boca Raton,
Florida 33431.
GARANTÍA LIMITADA DE 1 AÑO
Sunbeam Products, Inc. (“Sunbeam”), o en Canadá, Newell Brands Canada ULC (“NBC”), garantiza que por un período
de uno año a partir de la fecha de compra, este producto estará libre de defectos de materiales y mano de obra.
Sunbeam (o NBC), a su elección, reparará o reemplazará este producto o cualquier componente del mismo que
presente defectos durante el período de garantía. El reemplazo se realizará por un producto o componente nuevo o
reparado. Si el producto ya no estuviera disponible, se lo reemplazará por un producto similar de valor igual o
superior. Ésta es su garantía exclusiva. No intente reparar o ajustar ninguna función eléctrica o mecánica de este
producto. Al hacerlo elimínará ésta garantía.
La garantía es válida para el comprador minorista original a partir de la fecha de compra inicial y la misma no es
transferible. Conserve el recibo de compra original. Para solicitar servicio en garantía se requiere presentar un recibo
de compra. Los agentes y centros de servicio de Sunbeam (o NBC) o las tiendas minoristas que venden productos de
Sunbeam (o NBC) no tienen derecho a alterar, modificar ni cambiar de ningún otro modo los términos y las
condiciones de esta garantía. Esta garantía no cubre el desgaste normal de las piezas ni los daños que se produzcan
como resultado de uso negligente o mal uso del producto, uso de voltaje incorrecto o corriente inapropiada, uso
contrario a las instrucciones operativas, y desarme, reparación o alteración por parte de un tercero ajeno a Sunbeam o
a un Centro de Servicio autorizado por Sunbeam. Asimismo, la garantía no cubre actos fortuitos tales como incendios,
inundaciones, huracanes y tornados.
¿Cuál es el límite de responsabilidad de Sunbeam’s (o NBC’s) ?
Sunbeam (o NBC) no será responsable de daños incidentales o emergentes causados por el incumplimiento de alguna
garantía o condición expresa, implícita o legal.
Excepto en la medida en que lo prohíba la ley aplicable, cualquier garantía o condición implícita de comerciabilidad o
aptitud para un fin determinado se limita, en cuanto a su duración, al plazo de la garantía antes mencionada.
Sunbeam (o NBC) queda exenta de toda otra garantías, condiciones o manifestaciones, expresa, implícita, legal o de
cualquier otra naturaleza. Sunbeam (o NBC) no será responsable de ningún tipo de daño que resulte de la compra,
uso o mal uso del producto, o por la imposibilidad de usar el producto, incluidos los daños incidentales, especiales,
emergentes o similares, o la pérdida de ganancias, ni de ningún incumplimiento contractual, sea de una obligación
esencial o de otra naturaleza, ni de ningún reclamo iniciado contra el comprador por un tercero. Algunas provincias,
estados o jurisdicciones no permiten la exclusión o limitación de los daños incidentales o emergentes ni las limitaciones
a la duración de las garantías implícitas, de modo que es posible que la exclusión o las limitaciones antes mencionadas
no se apliquen en su caso. Esta garantía le otorga derechos legales específicos y es posible que usted tenga otros
derechos que varían de un estado, provincia o jurisdicción a otro.
Cómo solicitar el servicio en garantía
En los Estados Unidos
Si tiene alguna pregunta sobre esta garantía o desea recibir servicio de garantía, póngase visite nuestro sitio web
www.holmesproducts.com.
En Canadá
Si tiene alguna pregunta sobre esta garantía o desea recibir servicio de garantía, póngase visite nuestro sitio web
www.holmesproducts.com.
En los Estados Unidos, esta garantía es ofrecida por Sunbeam Products, Inc. Florida 33431. En Canadá, esta garantía
es ofrecida por Newell Brands Canada ULC, 20 B Hereford Street, Brampton, Ontario L6Y 0M1. Si usted tiene otro
problema o reclamo en conexión con este producto, por favor escriba al Departamento de Servicio al Consumidor.
POR FAVOR NO DEVUELVA ESTE PRODUCTO A NINGUNA DE ESTAS DIRECCIONES NI AL LUGAR DE
COMPRA.
PREGUNTAS FRECUENTES
PREGUNTAS RESPUESTAS
Cuáles son las variables que afectan
el tiempo de funcionamiento?
El tiempo de funcionamiento estimado de este humidificador está basado en
las condiciones ambientales promedio. El tiempo de funcionamiento actual de
su humidificador depende de varios factores tales como :
El intercambio de aire en el cuarto donde se encuentra el humidificador.
La estructura del cuarto donde se encuentra el humidificador.
La temperatura del cuarto donde se encuentra el humidificador.
Los niveles de humedad en el cuarto donde se encuentra el humidificador.
La actividad de los ocupantes y la secuencia en que se abren y cierran las
puertas del cuarto donde se encuentra el humidificador.
El número de muebles presentes en el cuarto donde se encuentra el
humidificador.
Cómo quito la película del tanque de
agua?
Consulte las instrucciones diarias de mantenimiento. Se recomienda una
limpieza regular.
Cómo puedo extender el tiempo de
funcionamiento?
Haga funcionar la unidad en el modo más bajo.
Si su unidad tiene electrónicos, ajústela al nivel de humedad deseado. La
unidad se encenderá y apagará, extendiendo el tiempo de
funcionamiento.
Llene el tanque al máximo, colóquelo en la base, deje que el agua se
vacíe en la base hasta que deje de burbujear, luego llene nuevamente el
tanque al máximo. Esto asegura una capacidad máxima de agua que
extenderá el tiempo de funcionamiento.
DIAGNÓSTICO DE PROBLEMAS
PROBLEMA
POSIBLE CAUSA SOLUCIÓN
La unidad no se
enciende.
* No está enchufada.
* El omacorriente no funciona.
4 Enchúfela.
4 Haga reemplazar el tomacorriente por un
electricista matriculado.
Salida de vapor mínima
o nula.
* El filtro no ha absorbido el
agua.
*
La niebla fría es invisible.
4 Espere 30 minutos para que el filtro absorba el
agua.
4 Funcionamiento en configuración High (alta) (II).
El filtro se pone marrón. * El filtro ha absorbido
minerales.
4 Reemplace su filtro (HWF62) llamando al
1-800-546-5637, o visite
www.holmesproducts.com
.
Si tiene preguntas relacionadas con este producto o si está interesado en conocer otros productos Holmes
®
, póngase
en contacto con nuestro Departamento de Servicio al Cliente: llame al 1-800-546-5637 o visite nuestro sitio web
www.holmesproducts.com. Para preguntas relacionadas con el reciclaje y la correcta eliminación de este producto,
por favor póngase en contacto con su centro local de gestión de residuos.
If you have any questions regarding your product or would like to learn more about other Holmes
®
products, please
contact our Consumer Service Department at 1-800-546-5637 or visit our website at
www.holmesproducts.com. For inquiries regarding recycling and proper disposal of this product, please contact your
local waste management facility.
STORAGE INSTRUCTIONS
When not using your humidifier for an extended period of time:
1. Dispose of the filters. DO NOT leave in unit.
2. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit
when storing. Leaving water in the unit may render the unit inoperable for the following season.
3. Place the humidifier in the original carton and store in a cool, dry place.
4. Order your replacement filter for next year’s use.
REPLACEMENT ACCESSORIES
To order the replacement accessories you can do any of the following:
Visit your local retailer
Go to
www.holmesproducts.com
Call Consumer Service at
1-800-546-5637
INSTRUCCIONES PARA GUARDAR
Cuando no utilice su humidificador durante un período prolongado de tiempo:
1. Elimine los filtros. NO los deje dentro de la unidad.
2. Limpie y seque bien el humidificador según se detalla anteriormente en la sección: instrucciones de mantenimiento
semanales. NO deje agua dentro de la unidad cuando guarde el humidificador. Si queda agua, la unidad podría quedar
inutilizable para la próxima temporada.
3. Coloque el humidificador en su empaque original y guárdelo en un lugar fresco y seco.
4. Encargue su filtro de repuesto para el próximo año.
ACCESORIOS DE REPUESTO
Puede ordenar accesorios de repuesto de una de las siguientes formas:
Visite su distribuidor local
Valla a
www.holmesproducts.com
Llame a servicio al consumidor al 1-800-546-5637
Owners Guide
HCM1100
Cool Mist
Humidifier
FILTER# : HWF62
FILTER TYPE : WICK
Manual del propietario
HCM1100
con rocío fresco
Humidificador
FILTRO# : HWF62
FILTRO TIPO : WICK
LEA Y CONSERVE ESTAS IMPORTANTES INSTRUCCIONES
FILTRO
DE REPUESTO
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS
Question and Answer IconNeed help?

Do you have a question about the Holmes HCM1100 and is the answer not in the manual?

Summary

IMPORTANT SAFETY INSTRUCTIONS

General Electrical Safety Precautions

Essential safety measures for operating electrical appliances to prevent fire, shock, and injury.

Humidifier Placement and Usage

Guidelines for safe humidifier placement, water exposure, operation, and preventing damage.

Polarized Plug Safety

Explanation and warning regarding the polarized plug to reduce the risk of electric shock.

FEATURES AND OPERATIONS

General Operating Tips

Key operational points, including tank water management, unit movement, and aromatherapy cup use.

Power Cord Safety

Guidance on selecting and using extension cords safely to prevent entanglement or tripping.

Cool Mist Humidification Process

Explanation of how the humidifier draws air, filters moisture, and releases cool mist.

Using the Aromatherapy Cup

Instructions for using the aromatherapy cup with essential oils, warning against adding oils to the water tank.

Pre-Operation Setup

Steps to prepare the humidifier before initial use, including turning it off and selecting a location.

Water Tank Filling Guide

Detailed instructions for filling the water tank, including enhancement tablets and cap sealing.

CLEANING AND MAINTENANCE

Maintenance Importance

Importance of proper maintenance for efficient operation and preventing micro-organism growth.

Daily Cleaning Procedures

Procedures for daily cleaning, including draining, rinsing, and refilling humidifier components.

Weekly Cleaning Procedures

Steps for weekly cleaning, including descaling with vinegar and disinfecting with bleach.

TROUBLESHOOTING AND FAQS

Troubleshooting Common Problems

Solutions for common humidifier issues like no power, low mist output, or discolored filter.

Frequently Asked Questions (FAQs)

Answers to common user questions about run time, tank film removal, and extending operation.

STORAGE INSTRUCTIONS

Long-Term Storage Guide

Guidelines for storing the humidifier for extended periods, including filter disposal and cleaning.

Ordering Replacement Parts

Information on how to order replacement filters and other accessories for the humidifier.

WARRANTY INFORMATION

1-Year Limited Warranty Details

Details of the one-year limited warranty, coverage, exclusions, and liability limitations.

Warranty Service & Support

Instructions on how to obtain warranty service and contact support in the US and Canada.

Overview

This document describes the Holmes Cool Mist Humidifier, model HCM1100, a household appliance designed to add moisture to dry indoor air, improving comfort and health. It utilizes a cool, invisible mist humidification system, drawing dry air through a rear intake grill and passing it through a moisture-laden wick filter. This filter retains minerals and deposits from the water, and the resulting moist air is then directed back into the room from the top air grill. The system is designed to provide a cool mist output that is typically not visible, which is normal for this type of humidification.

Usage Features:

The humidifier is designed for straightforward operation and includes several features to enhance user experience and ensure effective humidification.

  • Placement: For optimal performance and to prevent damage, the humidifier should be placed on a firm, flat, level, and moisture-resistant surface, at least 4 inches (10 cm) away from a wall. It should not be placed on rugs, carpets, or finished floors that could be damaged by moisture. Placing it on an inside wall near an electrical outlet is recommended, away from heat sources like stoves or radiators.
  • Power and Control: The unit operates on a 120V AC electrical outlet and features a 2-Speed Humidity Control/Power Knob. Users can adjust the humidification rate by moving the knob to the HI (2) position for maximum output or the LO (1) setting for a lower rate. It takes approximately 30 minutes for the filter to fully absorb water and for the unit to reach its maximum moisture output.
  • Water Tank and Filling: The humidifier holds about 1 gallon of water in its tank and base, capable of producing up to 1 gallon of water in a 24-hour period, depending on room humidity and temperature. To fill, the tank is removed from the base, turned upside down, and the tank cap is twisted off counter-clockwise. It should be filled with cool, fresh tap water; warm water should be avoided to prevent leaking. The tank cap must be replaced FIRMLY.
  • Tank Cap Tablet Holder: A unique feature is the cage located on the tank cap, designed to hold humidifier enhancement tablets. These tablets treat the water before it passes into the humidifier base. To use, the top of the green cage is popped off, a tablet is placed inside, and the cage top is closed. Only one tablet should be used per tank filling.
  • Aromatherapy Cup: An aromatherapy cup is integrated into the top grill of the humidifier. Users can pour designated essential oils into this cup to diffuse scents into the room. It is crucial NOT to add essential oils directly into the water tank.
  • Run Time Management: To extend run time, users can operate the unit on the lowest setting. If the unit has electronic controls, setting it to a desired humidity level will allow it to cycle on and off, conserving water. Filling the tank completely, allowing water to empty into the base until bubbling stops, and then refilling ensures maximum water capacity and extended run time.
  • Safety Precautions: The manual emphasizes numerous safety instructions, including never operating the unit without water, not moving it while operating or still warm, and always unplugging it before refilling or moving. It also warns against placing anything over the moisture outlet, inserting objects into openings, or operating with a damaged cord or plug. The appliance has a polarized plug for safety, which should not be modified.

Maintenance Features:

Regular cleaning and maintenance are crucial for the humidifier's efficient operation, to prevent the growth of algae or bacteria, and to prolong its lifespan.

  • Filter Replacement: The wick filter traps waterborne minerals and sediment. The frequency of filter replacement depends on water hardness, but under normal continuous use, a new filter should be replaced every 30 days. Replacement filters (model HWF62) can be purchased from local retailers or directly from the manufacturer.
    • Filter Replacement Process: To replace the filter, the unit must be switched OFF and unplugged. The tank and main housing are removed to access the base tray. The old filter is discarded, and weekly cleaning instructions are followed. A new filter is then inserted into the filter support in the base, followed by replacing the main housing and tank.
  • Daily Maintenance:
    1. Ensure the unit is OFF and unplugged.
    2. Remove the housing and tank, placing them in a sink or tub.
    3. Carry the base to the sink, remove the wick, drain remaining water, and rinse thoroughly to remove sediment or dirt. Wipe clean and dry.
    4. Drain and thoroughly rinse the water tank, wiping it clean and dry.
    5. Replace the filter and housing, then refill the tank with cool tap water.
    6. Follow operating instructions.
  • Weekly Maintenance (Remove Scale):
    1. Repeat steps 1-4 of daily maintenance.
    2. Clean the base by partially filling it with 8-oz cups of undiluted white vinegar or Cleanse Clean® solution (Model S1710). Let it stand for 20 minutes, cleaning interior surfaces with a soft brush. Remove scale by wiping with a cloth dampened with undiluted white vinegar.
    3. Rinse with clean warm water to remove the cleaning solution before disinfecting.
  • Weekly Maintenance (Disinfect Humidifier Base and Tank):
    1. Fill the humidifier tank halfway with water and 1/2 tablespoon of chlorine bleach.
    2. Let the solution stand for 20 minutes, swishing every few minutes to wet all surfaces.
    3. Carefully empty the tank after 20 minutes and rinse with warm water until no bleach smell is detected. Dry with a clean cloth or paper towel.
    4. Place the filter back into the tank, refill the water tank as directed in Operating Instructions, and turn the unit on.
  • Aromatherapy Cup Cleaning: The aromatherapy cup should be cleaned with a slightly wet cloth or cotton stick. Alcohol should NOT be used for cleaning.
  • Storage Instructions: When storing the humidifier for an extended period, dispose of the filters (do not leave them in the unit). Clean, rinse, and thoroughly dry the humidifier as per weekly maintenance instructions, ensuring no water remains in the unit. Store the humidifier in its original carton in a cool, dry place. It is recommended to order a replacement filter for the next year's use.

The manual also provides troubleshooting tips for common issues like the unit not turning on, minimal mist output, or the filter turning brown, offering solutions such as checking the power, allowing time for the filter to absorb water, operating on a higher setting, or replacing the filter. It also addresses frequently asked questions regarding run time variables and methods to extend run time.

Holmes HCM1100 Specifications

General IconGeneral
Humidifier TypeCool Mist
Water Tank Capacity1.1 gallons
Run TimeUp to 24 hours
Weight4.5 pounds
FilterYes
ColorWhite
Power SourceElectric
Filter TypeWick filter

Related product manuals