The HoMedics Duo Quartz IPL-HH300-GB is a home-use salon hair reduction system designed for fast, safe, and long-lasting hair removal. It utilizes both Intense Pulsed Light (IPL) and Advanced Fluorescence Technology (AFT) to reduce hair growth permanently.
Function Description:
The Duo Quartz works by targeting hair follicles below the skin's surface, reducing hair growth with minimal pain. It offers two treatment modes:
- Freeglide AFT™ (Levels 1-3): This mode delivers up to 1 pulse per second, allowing for fast and easy treatments that are comfortable even on sensitive skin. Users can hold the green trigger button down and glide the device across the skin, maintaining constant contact. For maximum coverage, it's necessary to repeatedly pass the device over the same area up to 5 times. The higher the level, the slower the device needs to be glided due to a slower pulse rate as more energy is released.
- IPL Single Shot (Levels 4-5): This mode provides additional control for higher power treatments. Users press the green trigger button, hold the device against the skin, and wait for a flash before moving to the next treatment area. This method is recommended for high energy levels.
The device is suitable for use on various body areas including legs, underarms, bikini line, chest, stomach, arms, and on the face below the cheekbones. It is not recommended for use on the face by men, over mucous membranes (nose and ears), over piercings or metal items, or on tanned skin.
Important Technical Specifications:
- Emitted Light Spectrum: 480nm~1200nm Max.
- Emitted Energy Flux: 5 [Joules/cm²]
- Selectable Energy Levels: 5 levels
- Treatment Area (regular window): 3 [cm²]
- Max pulses in lamp: up to 100,000
- Power Supply: 100-240 VAC, 50-60Hz
- Technology: Home use IPL and AFT
Usage Features:
- Quick Start Guide:
- Ensure the skin is shaved, clean, and dry.
- Connect the power lead to the Duo Quartz and plug into the mains. The blue/white skin level indicator lights will flash and turn off, and the green status light will illuminate.
- Press the power button to switch on the device.
- Press the power button to select an appropriate level for your skin tone. A skin test is recommended before first use.
- Hold the device against the treatment area, ensuring the yellow treatment window is in full contact with the skin. The green status indicator will stop flashing when good skin contact is made.
- For levels 1-3 (AFT Freeglide™), hold the green trigger button down and glide. For levels 4 & 5 (IPL single shot), press the green trigger button, hold, and wait for the flash.
- Skin Test: A spot test is crucial 48 hours prior to full treatment to determine skin reaction and optimal energy level. Start at level 1, deliver a pulse, then increase the level by 1 and repeat until the maximum comfortable level is reached. Wait 48 hours to examine the tested area for adverse effects like severe redness or blistering.
- Treatment Protocol:
- Body Treatment: Follow the determined energy level from the spot test.
- Freeglide AFT (Levels 1-3): Can be repeated up to twice a week on an ongoing basis.
- Single Shot IPL (Levels 4-5): Sessions should be separated by a minimum of 2 weeks. Initially, treat every two weeks for 6 treatments, then top-up as required with at least a two-week interval. Not recommended for skin type 5.
- Facial Treatment: Always use the included precision facial adapter. Start at level 1 and increase only if comfortable. Avoid areas above the cheek line, around eyes, eyebrows, eyelashes, nose, and ears. Use a mirror to ensure correct placement. Facial hair may require more sessions due to hormonal factors.
- Upper Lip Treatment: Place the applicator as indicated, repeat up to 5 times. Avoid nostrils and lips; mask lips with paper if necessary.
- Cheek and Jaw Treatment: Treat each area up to 5 times, moving from one side to the other.
- Neck and Chin Treatments: Treat each area up to 5 times, moving from one side to the other. Note that skin on the lower third of the neck is more sensitive.
- Hair and Skin Type Suitability: The device works best on dark hair or hair with more melanin. Brown and light brown hair will respond but may require more sessions. Red, white, grey, or blond hair show limited response. The device is suitable for skin types 1-4, with type 5 requiring more treatments and type 6 being unsuitable due to high melanin absorption.
- What to Expect: Users will experience a bright flash, a popping noise with each pulse, a sensation of warmth, and possibly a mild stinging sensation. Fan noise will be present, but lower than a hair dryer.
- Post-Treatment Care: Apply a calming lotion like Aloe Vera. Avoid peeling/bleaching creams for at least 24 hours. Avoid direct sun exposure for at least 2 weeks; use SPF 30 or higher if unavoidable. Do not wax or pluck hairs from treated areas. Hair will naturally fall out within 2 weeks.
Maintenance Features:
- Cleaning: Turn off and unplug the unit before cleaning. Clean the applicator head cover after every session using a dry, clean cloth.
- Storage and Transport Conditions:
- Temperature: -15°C to 55°C
- Humidity: 10-90%rH
- Pressure: 50-105KPa
- Operating Conditions:
- Temperature: 10°C to 35°C
- Humidity: 35-75%rH
- Max Operating Altitude: 70-105KPa
- General: Keep the device dry; never submerge it in water. Do not rinse components with any liquid.
Safety Precautions:
- Do not use if pregnant or nursing, have skin cancer, epilepsy, recent radiation/chemotherapy, active implants (pacemakers, insulin pumps), damaged/broken skin, history of Herpes/Psoriasis in treatment area, keloidal scar formation, recent Tetracycline antibiotics, Retinoids, Accutane, Retin-A, photosensitivity, metabolic conditions (diabetes), recent skin peel/resurfacing (within 6-8 weeks), strong sun/artificial tanning exposure (within 30 days), or dark spots/moles/blisters in treatment area.
- NEVER use flammable liquids (alcohol, acetone) to clean skin before use.
- Do not use on tattoos, permanent make-up, or intimate body parts (nipples, genitalia, anus).
- Stop use immediately if extreme redness, blistering, or burns occur.
- Do not look directly at the light.
- Do not apply continuous pulses on one spot or return to a previously treated spot within 10 seconds.
- Do not open or repair the device.
- Disconnect power cord after use.
- Do not use in wet environments or if dropped in liquid.
- Keep out of children's reach.
- This appliance is not intended for use by persons with reduced physical, sensory, or mental capabilities unless supervised. Children aged 14 and above can use it with supervision. Not for children to play with.
- Do not use near bathtubs, showers, basins, or other vessels containing water.
The HoMedics Duo Quartz comes with a 2-year guarantee and a 120-day money-back satisfaction guarantee in the UK & Ireland, subject to specific terms and conditions.