desired, HomeSeer users can adjust this interval (0-2678400 seconds) by accessing the settings on the Z-Wave tab of
the root device. Note: battery sensor operation is disabled on units that are line powered.
Z-Wave Association Information
HS-LS100+ supports Group 2 association. Group 1 reports the sensor’s status and battery if running on batteries.
Group 2 is assigned to send BASIC SET command.
Notification
a. When the Overheat detected, send Heat Alarm (04) and Overheat detected, Unknown
Location(0x02);
b. When Under heat detected, send Heat Alarm (04) and under heat detected, Unknown
Location(0x06);
c. When Water leak detected, send Water Alarm (05) and Water leak detected, Unknown
Location(0x02);
d. When Tampering detected, send Home Security (07) Tampering, Product covering
removed(0x03);
Notes
If your home controller supports “S2” security encryption, the Leak Sensor may be added as a ‘secure’ device to
your network. This will not effect the functionality of the unit.