Important Notes
Codes: Install in accordance with all local and
national electrical codes.
Power: The Hybrid Repeater can be powered from
EITHER of two sources:
1. Adapter power. Use only the adapter
provided with the Hybrid Repeater (Lutron
model # T120-9DC-3-WH).
Caution - Using an adapter not rated at the
following specifications could damage the
repeater and possibly overheat the adapter.
• Input: 120 V 60 Hz
• Output: 9 V 300 mA
NEC
® Class 2; IEC PELV
2. Link power. Use only power supplied via a
HomeWorks Processor Hybrid Repeater
Link (8 Series
TM or 4 SeriesTM Processors
only) or a HomeWorks auxiliary power
supply. (See section about the HWI-PS in
the HomeWorks Technical Reference
Guide or Application Note HW-104.) Each
Hybrid Repeater counts as 15 LEDs.
Note: An RF Processor does not supply
power on the Hybrid Repeater Link.
Environment: Ambient operating temperature:
32-104 °F (0-40 °C), 0-90% humidity, non-condensing.
Indoor use only.
Hybrid Repeater Wiring: Hybrid Repeater Link wiring
must be in a daisy chain configuration. The total
length of any single wire run on the Hybrid Repeater
Link may be up to 1000 feet (305 m). The Hybrid
Repeater Link (all wire runs) may contain up to five (5)
Hybrid Repeaters total. Refer to Hybrid Repeater Link
(Wired) Communications (page 3).
Please Read Before Installing
Installation Instructions
Overview
HomeWorks Hybrid Repeaters add RF capability to
HomeWorks P5 processors configured with a Hybrid
Repeater Link and provide an additional coverage
area for radio frequency (RF) signals sent between
HomeWorks RF Dimmers/Switches, RF Shades, RF
Keypads, and RF Processors. Each repeater covers a
sphere of approximately 2500 square feet (232 m
2
) of
living space. Up to five (5) repeating devices may be
placed in a HomeWorks RF system (a HomeWorks
RF Processor counts as one of the repeating devices).
Hybrid Repeater with plug-in adapter
HR-REP-120
FCC Information
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, persuant to part 15 of the FCC rules.
Operation is subject to the following:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Non-P5
RF Processor
P5
RF Processor
P5 4 Series*
HRL
Processor
P5 8 Series
HRL
Processor
Adapter
Power
YES
YES
YES
YES
Link
Power
NO
NO
YES
YES
Repeater-to-
Repeater Wiring
YES
YES
YES
YES
Repeater-to-
Processor Wiring
NO
YES
YES
YES
Power Options
Hybrid Repeater Link
Communications
Compatibility Considerations
* Hybrid Repeater Link is available on models H4P5-HRL-120 and
H4P5-H48-HRL-120 only.
Cleaning: To clean, wipe with a clean damp cloth. DO
NOT use any chemical cleaning solutions.
Device Placement: HomeWorks Hybrid Repeaters
must be located within 30 feet (9 m) of the RF
Dimmers, Switches, Shades, and Keypads they are
covering. Hybrid Repeaters must also be within 60
feet (18 m) of an RF Processor or another repeater
when using the RF Link for repeater-to-repeater or
repeater-to-processor communication. When using the
Wired Link for repeater-to-repeater or repeater-to-
processor communication, a total wire length of 1000
feet (305 m) may be used.
Hybrid Repeater
HR-REP
9 V 300 mA (adapter power)
or
15 V 300 mA (link power)
Plug-in Adapter
T120-9DC-3-WH
Input: 120 V 60 Hz 6.5 W
Output: 9 V 300 mA
NEC Class 2
IEC PELV