GENERATOR SAFETY

IMPORTANT SAFETY INFORMATION

General warnings and guidance for safe generator operation and handling.

Carbon Monoxide Hazards

Warns about CO poisoning and provides instructions for safe generator operation.

CO-MINDER:

Explains the CO-MINDER system that automatically stops the engine due to CO levels.

Electric Shock Hazards

Details risks of electric shock and precautions for using the generator safely.

Fire and Burn Hazards

Warns about hot surfaces and flammable materials, providing safety measures.

Refuel With Care

Provides safety instructions for refueling the generator, highlighting flammability risks.

INITIAL USE INSTRUCTIONS

ENGINE OIL

Instructions for adding engine oil to the generator before first use.

FUEL

Guidance on adding fuel, including safety warnings and checking the fuel level.

CONTROLS & FEATURES

CO-MINDER (CO Shut-off System)

Explains the CO-MINDER system and its function to prevent CO poisoning.

Oil Alert;Check Indicator

Warns of low oil levels and automatically stops the engine.

BEFORE OPERATION

Check the Engine

Details pre-operation checks for engine leaks, oil, air filters, and fuel level.

ENGINE OIL LEVEL CHECK

Step-by-step instructions for checking the engine oil level.

SAFE OPERATING PRECAUTIONS

Reinforces safety guidelines, especially regarding enclosed spaces and exhaust.

OPERATION

STARTING THE ENGINE

Detailed steps for starting the generator, including electric and manual methods.

HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM)

Guides on how to restart the generator after it has been stopped by the CO-MINDER.

AC OPERATION

Instructions for connecting and operating appliances using the generator's AC output.

STANDBY POWER

Guidance on connecting the generator to a building's electrical system safely.

SERVICING YOUR GENERATOR

MAINTENANCE SAFETY

General safety precautions to follow before performing maintenance tasks.

MAINTENANCE SCHEDULE

Provides a schedule for regular maintenance tasks based on time or operating hours.

ENGINE OIL CHANGE

Detailed instructions for draining and refilling the engine oil.

SPARK PLUG SERVICE

Instructions for inspecting, cleaning, and replacing the spark plug.

STORAGE

TAKING CARE OF UNEXPECTED PROBLEMS

ENGINE WILL NOT START

Troubleshooting guide for common causes of the engine failing to start.

ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR FLASHING

Troubleshooting when the engine stops due to CO detection.

CONSUMER INFORMATION

Distributor’s Limited Warranty

Details the terms, coverage, and conditions of the generator's limited warranty.

Summary

GENERATOR SAFETY

IMPORTANT SAFETY INFORMATION

General warnings and guidance for safe generator operation and handling.

Carbon Monoxide Hazards

Warns about CO poisoning and provides instructions for safe generator operation.

CO-MINDER:

Explains the CO-MINDER system that automatically stops the engine due to CO levels.

Electric Shock Hazards

Details risks of electric shock and precautions for using the generator safely.

Fire and Burn Hazards

Warns about hot surfaces and flammable materials, providing safety measures.

Refuel With Care

Provides safety instructions for refueling the generator, highlighting flammability risks.

INITIAL USE INSTRUCTIONS

ENGINE OIL

Instructions for adding engine oil to the generator before first use.

FUEL

Guidance on adding fuel, including safety warnings and checking the fuel level.

CONTROLS & FEATURES

CO-MINDER (CO Shut-off System)

Explains the CO-MINDER system and its function to prevent CO poisoning.

Oil Alert;Check Indicator

Warns of low oil levels and automatically stops the engine.

BEFORE OPERATION

Check the Engine

Details pre-operation checks for engine leaks, oil, air filters, and fuel level.

ENGINE OIL LEVEL CHECK

Step-by-step instructions for checking the engine oil level.

SAFE OPERATING PRECAUTIONS

Reinforces safety guidelines, especially regarding enclosed spaces and exhaust.

OPERATION

STARTING THE ENGINE

Detailed steps for starting the generator, including electric and manual methods.

HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM)

Guides on how to restart the generator after it has been stopped by the CO-MINDER.

AC OPERATION

Instructions for connecting and operating appliances using the generator's AC output.

STANDBY POWER

Guidance on connecting the generator to a building's electrical system safely.

SERVICING YOUR GENERATOR

MAINTENANCE SAFETY

General safety precautions to follow before performing maintenance tasks.

MAINTENANCE SCHEDULE

Provides a schedule for regular maintenance tasks based on time or operating hours.

ENGINE OIL CHANGE

Detailed instructions for draining and refilling the engine oil.

SPARK PLUG SERVICE

Instructions for inspecting, cleaning, and replacing the spark plug.

STORAGE

TAKING CARE OF UNEXPECTED PROBLEMS

ENGINE WILL NOT START

Troubleshooting guide for common causes of the engine failing to start.

ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR FLASHING

Troubleshooting when the engine stops due to CO detection.

CONSUMER INFORMATION

Distributor’s Limited Warranty

Details the terms, coverage, and conditions of the generator's limited warranty.

Honda EU3000IS1AG Specifications

General IconGeneral
Max Output3000 watts
Rated Output2800 watts
Displacement196 cc
Fuel Tank Capacity3.4 gallons
AC Voltage120V
Rated AC Current23.3A
DC Output12V, 8A
Fuel TypeGasoline
TypeInverter Generator
Engine Type4-Stroke OHV
Noise Level58 dB(A)
Dimensions (L x W x H)25.9 x 17.6 x 22.0 inches
Starting SystemRecoil Start
Outlets2x 120V 20A
Run Time at 1/4 Load20 hrs