OPERATION
68
When operating generators in parallel operation, if one generator emits exhaust
toward the other, the CO-MINDER (CO Shut-off System) of the generator that is
receiving the exhaust may stop the engine. Pay attention to the following for
placing generators in parallel operation.
Align the two generators so that their mufflers are on the same line and exhaust in
the same direction.
Place the generator so that the muffler is pointed in the same direction as the
wind is blowing and the exhaust is directed away from buildings, other structures,
or vehicles.
EXHAUST
EXHAUST
ON THE SAME LINE
MUFFLER TIP
WIND DIRECTION
WIND DIRECTION
This generator may detect exhaust from
the adjacent generator and will stop the
engine.
OK INCORRECT
31Z376200.book 68 ージ 020年2月14日 金曜日 午前10時39

Table of Contents

Other manuals for Honda Eu7000is

Questions and Answers:

Honda Eu7000is Specifications

General IconGeneral
EngineHonda GX390 EFI
Fuel TypeGasoline
Rated Power5500W
Max Power7000W
Dimensions33.4" x 27.6" x 28.4"
Rated Voltage120/240V
Rated Amperage45.8/22.9A
Engine Displacement389cc
Noise Level at 1/4 Load52 dBA
Noise Level at Rated Load58 dBA
Starting SystemElectric
Run Time at 1/4 Load18 hrs
Dry Weight261 lbs
Outlets1x 120/240V 30A Locking Plug