HE120 BY-PASS DRUM HUMIDIFIER
5 69-1110EF—03
TROUBLESHOOTING YOUR HUMIDIFIER
Problem What To Look For What To Do
Low humidity Furnace blower not
operating.
Reset circuit breaker or check for blown fuse.
Check that the furnace power is on.
Check all external wiring connections.
Check the humidity control setting.
Call a professional heating contractor.
Rapid air changes. Drafts
(cold air is dry and is an
added load to the
humidifier).
Keep doors and windows closed.
Close fireplace damper when not in use.
Keep exhaust fan running time to a minimum.
Seal around doors and windows.
High humidity Condensation on walls. Turn off the humidity control and water until condensation is
completely evaporated.
Heavy condensation on
windows.
Turn humidity control down low enough to eliminate
condensation caused by moisture from bathing, mopping,
cooking, etc. If moisture persists, more ventilation is needed.