HE360A,B POWERED FLOW-THROUGH HUMIDIFIER
3 69-1176-1
OPERATING YOUR HUMIDIFIER
HE360A
Your Honeywell HE360A Humidifier from Honeywell is
controlled by the H8908B Convertible Humidity
Control. The convertible humidity control is installed
either on an interior wall in the living area, or on the
return air duct. Choose the humidity control setting
using the combination relative humidity/outdoor
temperature setting scale on your humidity control
dial. Match the dial setting to the outdoor temperature
for optimizing the humidity level while reducing the
moisture condensation on your windows. The table
below can also be used to adjust the humidity control
to the recommended setting.
NOTE: As the outside temperature drops, the recommended humidity control setting
is lowered to accommodate for effects of dewpoint. These settings should
reduce the accumulation of moisture and ice on your windows and in other
areas of your home.
Some indoor activities such as cooking, showering and clothes drying can cause
excessive levels of humidity and start the accumulation of moisture on your windows.
NOTE: If this condition persists for more than a few hours, set the humidity control to
the lowest setting to turn off the humidifier. If the condition does not improve,
ventilate your home to remove the moisture.
HE360B
Your Honeywell HE360B Humidifier is controlled by the
Honeywell H1008 Automatic Humidity Control with
HumidiCalc+™ Software. The automatic humidity control
is mounted in the return air duct where it can be exposed
to the air stream of the return air.
At Outside
Temperature
Recommended
Control Setting
At Outside
Temperature
Recommended
Control Setting
-20°F (-29°C) 15 +10°F (-12°C) 30
-10°F (-23°C) 20 +20°F (-7°C) 35
0°F (-18°C) 25 Above 20°F (-7°C) 40
Humidity Control
Régulateur d'humidité
-20 °
F
-10 °
F
0 °
F
+10 °F
+20 °
F
Over 20 °
F
15%
20%
25%
30%
35%
40%
HUMIDITY
SETTING
OUTDOOR
TEMPERATURE
-30 °C
-25 °
C
-20 °
C
-10 °
C
-5 °
C
Over 0 °C
M1469
4
M1281
7
H1008A
69-1176.fm Page 3 Friday, September 19, 2003 11:22 AM

Other manuals for Honeywell HE360A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HE360A and is the answer not in the manual?

Honeywell HE360A Specifications

General IconGeneral
Control TypeManual Humidistat
Voltage24V
Auto Shut-offNo
TypeEvaporative
HumidistatIncluded

Related product manuals