EasyManua.ls Logo

Honeywell PC3F1558IUF00 User Manual

Honeywell PC3F1558IUF00
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SPECIFICATION DATA
68-3083-02
PC3F1558IUF00 Hydronic
Circulating 3 Speed Pump
APPLICATION
The PC3F in-line, wet rotor circulator with universal flange is
designed for applications in closed-loop hydronic heating and
cooling systems, as well as in solar-powered systems. The
pump is non-submersible and for use in dry, frost-free, well-
ventilated installations.
SPECIFICATIONS
Rate of flow: Up to 15 gpm (56.8 lpm)
Pressure head: Up to 19.4 ft (6 m)
Voltage:
115 VAC +/- 10% 60Hz
Amperage:
See “Speed switching” on page 2.
Max. Pressure:
145 psi (at room temperature);
50 psi (at 200°F [93°C])
Temperature Range:
Ambient temperature: 32°F to 104°F (0°C to 40°C)
Media temperature: 14°F to 230°F (-10°C to 110°C) [to 200°F
(93°C) with optional check valve installed]
Storage Temperature: -40°F to 100°F (-40° to 66°C)
Standards:
Insulation Class F
Temperature class: TF 95
Fig. 1. Pump dimensions in in. (mm).
Shipping Weight: 7.8 lbs (3.54 Kg)
L1 L2 L3 L4 L5
6.5 (165.5) 5.5 (140) 4.7 (118) 6.6 (167) 3.2 (80.2)
M32832A
L2
L4
L3
L1
L5
Question and Answer IconNeed help?

Do you have a question about the Honeywell PC3F1558IUF00 and is the answer not in the manual?

Honeywell PC3F1558IUF00 Specifications

General IconGeneral
BrandHoneywell
ModelPC3F1558IUF00
CategoryWater Pump
LanguageEnglish

Summary

Application

Specifications

Rate of Flow

Specifies the maximum flow rate for the pump, up to 15 GPM.

Pressure Head

Indicates the maximum vertical distance the pump can lift water, up to 19.4 ft.

Voltage

Details the required operating voltage and frequency for the pump.

Amperage

Refers to the electrical current the pump draws, detailed on page 2.

Maximum Pressure Rating

Specifies the maximum pressure the pump can withstand at different temperatures.

Operating Temperature Range

Defines the acceptable ambient and media temperatures for pump operation.

Storage Temperature

Specifies the temperature limits for storing the pump.

Standards and Classifications

Lists insulation and temperature class standards the pump meets.

Materials and Media

Pump Materials

Lists the materials used for pump components like body, impeller, and shaft.

Fluid Compatibility

Describes the types of fluids, including glycol concentrations, the pump can handle.

Control and Protection

Speed Switching

Details the three-speed selection mechanism and its operation.

Motor Thermal Protection

Explains the integrated thermal overload protection for the motor.

Flange Connections

Universal Flange Details

Provides specifications for the universal flange, including bolt spacing and hole size.