INSTALLATION INSTRUCTIONS
66-1203-05
S9360A, S9361A,
S9380A, S9381A
Integrated Boiler Controllers
APPLICATION
These integrated boiler control modules provide ignition
sequence, flame monitoring and safety shutoff for
intermittent pilot spark ignition, or direct spark ignition
heating systems. They also provide limit rated water
temperature control with one or two sensors and display
interface capability for either “on-board” or remote user
interface applications.
S9360A—Spark Ignition, Intermittent Pilot, Remote
Display.
S9361A—Spark Ignition, Intermittent Pilot, “On board”
Display.
S9380A—Direct Spark Ignition, Remote Display.
S9381A—Direct Spark Ignition, “On board” Display.
Enabled with EnviraCOM™ communication capability
to support remote monitoring and diagnostics.
Limit-rated Temperature Sensing Probe.
Ignitor sensor type
two rod (separate ignitor and sensor)
one rod (combined ignitor and sensor)
SPECIFICATIONS
IMPORTANT:
The specifications given in this publication do
not include normal manufacturing tolerances.
Therefore, an individual unit may not match the
listed specifications exactly. Also, this product is
tested and calibrated under closely controlled
conditions, and some minor differences in
performance can be expected if those
conditions are changed.
Model Numbers
S—Switching Control
93—Integrated Hydronic Control Platform
6—Spark Ignition
8—Direct Spark Ignition
0—Remote Display Required
1—Integrated On-Board Display
A—Boiler Control
B—Water Heater Control
C—Pool Heater Control
1—No Circulator
2—On/Off Circulator
3—On/Off Circulator meeting CSD-1
2012 DOE Compliance and Operation
Operation of this control may delay the burner operation while the residual heat is circulated
out of the boiler.
NOTE: This operation may be different than earlier integrated boiler control
revisions which did not implement thermal purge.
Question and Answer IconNeed help?

Do you have a question about the Honeywell S9361A and is the answer not in the manual?

Honeywell S9361A Specifications

General IconGeneral
Input Voltage24 Vac
Switch ActionSPDT
Ignition TypeIntermittent Pilot (IP)
Trial for Ignition Time (sec)4
Frequency60 Hz
Operating Temperature Range (F)150 F
ApprovalsCSA

Summary

Installation Instructions

Specifications

Technical details and operational parameters of the controllers.

Model Numbers

List of available models and their specific features.

Electrical Ratings and Flame Monitoring

Installation and Environmental Considerations

Installation and Checkout Procedures

Product Installation Steps

Essential steps and considerations before product installation.

Preinstallation Safety Inspection

Mandatory safety checks required prior to installation.

Module Mounting Instructions

Instructions for selecting an appropriate mounting location.

Wiring Guidelines

Important Wiring Considerations

Critical points for proper and safe wiring connections.

Ignition Cable Connection

Specific instructions for connecting the ignition cable.

Ground Control System

Importance and method of grounding the control system.

Specific Ignition Timings

Wiring Diagrams

State Code Definitions

Temperature Control and Display

Sensor Mounting and Wiring

Troubleshooting Guide

Error Code Definitions