Installer setup ,
Setup
functions
Settings
&
Options
(factory
default
in
bold)
0500
Furnace
filter
change
reminder
0
1
2
3
4
5
6
Off
1 O-day run time (about 1 month)
30-day run
time
(about 3 months)
60-day run
time
(about 6 months)
90-day run time (about 9 months)
120-day run time (about 1 year)
365-day run
time
(about 3 years)
0510
Humidifier
pad
change
reminder
0
1
2
3
Off
90
calendar days
180 calendar days
365
calendar days
0520
UV
lamp
change
reminder
0
1
Off
365 calendar days
0530
Adaptive
Intelligent
RecoveryTM
1
0
On
Off
** See page
11
0540
Program
periods
4
2
4
program
periods
(Wake, Leave,
Return,
Sleep)
2 program periods (Wake, Sleep)
0580
Compressor
protection
5 5
minute
compressor
off
time
**
See
page
11
[Other options:
0,
1,
2,
3
or
4-minute
off
time]
0600
Heat
temperature
range
stop
90
Max.
heat
temperature
setting
is
90°F (32°C)
[Other options: 40-89°F (4°C
to
32°C)]
0610
Cool
temperature
range
stop
50
Min.
cool
temperature
setting
is
50°F
(10°C)
[Other options: 51-99°F (11°C
to
37°C)]
0640
Clock
format
12
12-hour
time
(i.e.,
"3:30
pm")
24 24-hour time (i.e., "15:30")
0650
Extended
fan
timer
(heat)
0
90
Off
Fan runs
for
90 seconds after call
for
heat ends
0660
Extended
fan
timer
(cool)
0
90
Off
Fan runs
for
90 seconds after call
for
cooling ends
0670
Keypad
lock
0
1
2
Keypad
unlocked
(fully
functional)
Partially locked (access
to
temperature settings only)
Fully locked
0680
Heat
temperature
control
2
1
3
Standard
temperature
control
(recommended)
Choose
if
room is warmer than set temperature
Choose
if
room does
not
reach set temperature
0690
Cool
temperature
control
2
1
3
Standard
temperature
control
(recommended)
Choose
if
room is cooler than set temperature
Choose
if
room does
not
reach set temperature
0700
Temperature
display
offset
0
Thermostat displays actual room temperature
[Other options: -3, -2,
-1,1,2,
3°F offset (-1.5°C
to
1.5°C)
0710
RESET
0
1
No
reset
Reset installer options & program schedule
to
factory
default (only date and
time
settings are retained)
9