Installation Guide
Specifications
Temperature
Ranges
•
Heat: 40°
to
90°F (4.5°
to
32°C)
•
Cool: 50°
to
99°F
(10°
to 37°C)
Operating
Ambient
Temperature
•
0°
to
120°F (-18°
to
48.9°C)
Shipping
Temperature
•
-30° to 150°F (-34° to 66°C)
Operating
Relative
Humidity
•
5%
to
90% (non-condensing)
Physical
Dimensions
•
4-9/16" H x 6" W x 1-3/8" D
•
116 mm H x 152 mm W x 35 mm D
Need Help?
For assistance with this product please
visithttp://yourhome.honeywell.com
or
call Honeywell Customer Care toll-free at
1-800-468-1502
Automation
and
Control
Solutions
Honeywell International Inc. Honeywell Limited-Honeywell Limitee
1985 Douglas Drive North 35 Dynamic Drive
Golden Valley,
MN
55422 Toronto, Ontario M1V 4Z9
http://yourhome.honeywell.com
*
Printed in U.S.A. on recycled
paper containing at least
10%
post-consumer paper fibers.
®
u.s.
Registered Trademark.
US
Patent No. 6595430, 0509151 and other patents pending.
© 2007 Honeywell International Inc.
69-1896E8-1
M.S.
Rev.
02-07
ell
Electrical
Ratings
Tenninal Voltage (50/60Hz)
Running Current
WHeating
(Powerpile)
W2
Heating
Y Cooling
Y2 Cooling
Aux
Auxiliary heat
OIB
Changeover
E Emergency heat
L Heat pump reset
20-30Vac
0.02-1.0 A
750
mV
DC
100
rnA
DC
20-30
Vac
0.02-0.6 A
20-30
Vac
0.02-1.0 A
20-30Vac
0.02-0.6 A
20-30Vac
0.02-1.0 A
20-30Vac
0.02-0.6 A
20-30Vac
0.02-1.0 A
20-30
Vac
0.02-0.6 A