EasyManua.ls Logo

Hongda USA HDT20A - User Manual

Hongda USA HDT20A
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
HDT20A HDT20B
Insulation Resistance Tester User's Manual
Safety Rules
Safety Warning
The designmanufacture and test are all up to the safety
standard IEC61010(safety demand of the electronic products), this
manual includes the safe using of the instrument and the safety
state of instrument, the warning and the safety rules that the users
must comply. Please read the manual before use.
Warning
Please read carefully and understand this manual before using
the instrument.
Please comply the regulation of the manual all the time, and
keep the manual for consultation.
When using the instrument for testing, wrong operation can
result in accident and instrument damage.
The Company reserves the right to modify the instructions, if the
instructions are to change without noticepls understand.
The symbols on the instrument mean that in order to operate
the instrument safely, the users are supposed to refer to the relating
description in this manual.
Danger is in order to avoid the probably serious or fatal
damage in some state and operation.
Warning is in order to avoid the danger of electric-shocking.
Notice means avoiding the damage to the instrument and
accurate measuring.
Danger
Please don't take measurement in the flammability place, the
spark maybe result in explosion.
Please don't operate the instrument if it is wet of the instrument
surface or of the user's hand.
When testing voltage, it probably result in person injury
because of the short circuit of the metal part and the testing lead.
Please don't exceed the maximum scope of the allowable range.
Don't open the battery cover when testing.
When taking the insulated measurement, please don't touch the
circuitry under test.
Warning
If there is abnormity from the instrument, please stop using.
For example: the instrument dilapidation or metal part exposure.
Please don't rotate the Function/Selection switch when the
testing lead is inserted into the instrument and connected to the
circuitry for testing.
Please don't install any substituting parts to the instrument or
carry on any unauthorized modification, instruments are sent back
to the Hongda Company when maintaining.
Please don't replace the battery when the instrument is in the
state of humidity.
Please sure the connection is fastness of all the testing
interfaces between the testing lead and the instrument.
Please sure the instrument is turned off when opening the
battery cover.
Notice
Before test, please sure the voltage selector switch is on the
proper location.
After test, please set the function switch to the range "OFF". If
it is available for a long time, please take out the battery for storage
Please don't put the instrument in the place of high
temperaturehumiditydew and strong light for a long time.
Please use the humid cloth or detergent to clean the instrument
case. Don't use the friction material or solvent.
If the instrument is wet, please make it dry then storage.
Symbol
The probability of electric-shocking
The instrument has double insulation or reinforcing insulation
Important operation(referring to the manual)
1.Preface
1.1 Thanks for use our products, you will get the
comprehensive technology support and service from our company.
1.2This manual is used for HDT20A/HDT20B insulation
resistance tester.
1.3 Before using the product, please read the manual
carefully and keep it well for reference.
1.4 The product is for high-voltage electric equipment tester,
please accord to the manual description to operate. And comply
strictly to the Nation's related regulations. For inappropriate
operation, it will probably result in equipment damage or person
safety danger.
1.5 Please consult our company when there is any question
as you read the manual or use the instrument.
2.Characteristics
2.1 HDT20A HDT20B is a electron controlled minitype
instrument, thereinto, the high voltage insulation resistance tester
has three insulation resistance for voltage test.
2.2 The design is up to the following safety standard:
IEC 1010
89/336/EEC(electromagnetism compatibility, Nov, 1992, EMC)
P73/23/EEC(product safety regulation: Nov, 6
th
, 1979,
low-voltage regulation: Feb,19th, 1973)
2.3 Automatically release voltage function:
2.4 Be used for the insulation resistance of all kinds of
electron equipment and insulation material, such as transformer
generator cable switch electric equipment and so on. Be used for
the maintenancetest and check of all the series of electric
equipment.
2.5 Rated voltage variable
HDT20A-- Rated voltage can be switched among 250V, 500V,
1000V by knob switch.
HDT20B-- Rated voltage can be switched among 1000V,
2500V by knob switch.
2.6 High voltage indication
There is the LED in the instrument(HV ON) indicating the high
voltage work state.
2.7 Low battery indication.
2.8 Battery drive, removing the operation of hand-cranked
generator.
2.9 3
1
/
2
digital display, reading clearly.
2.10 Th e measurement range for HDT20A is 0.1MΩ~1999M
Question and Answer IconNeed help?

Do you have a question about the Hongda USA HDT20A and is the answer not in the manual?

Summary

Safety Rules and Warnings

General Safety Warnings

Read and understand manual before use, comply with regulations, and keep for consultation.

Operational Hazards

Wrong operation can result in accident and instrument damage. Refer to symbols for safe operation.

Danger and Shock Warnings

Danger for fatal damage, Warning for electric-shocking danger. Notice for instrument damage.

Instrument Characteristics

Design Standards and Features

Designed to IEC 1010 and EMC/low-voltage regulations, featuring automatic voltage release.

Applications and Usage

Used for insulation resistance of electron equipment and materials, plus maintenance and testing.

Rated Voltage Variability

HDT20A: 250V, 500V, 1000V. HDT20B: 1000V, 2500V, switchable via knob.

Indicators and Power

Includes high voltage (HV ON) LED and low battery indicator; battery-powered operation.

Display and Measurement Range

Features a 3 1/2 digital display. HDT20A range: 0.1M-1999MΩ.

Technical Specifications

General and HDT20 A Specifications

Covers test conditions, low battery, insulation resistance, voltage withstand, and operating temp/humidity.

HDT20 A Specific Ranges

Details output voltage, current, resistance ranges (20MΩ, 200MΩ, 2000MΩ) and ACV.

HDT20 B Specific Ranges

Details output voltage, current, resistance ranges (20MΩ, 200MΩ, 2000MΩ, 20GΩ) and ACV.

Appearance and Safety Notices

Instrument Appearance Overview

Identifies key components like terminals, buttons, display, and indicators in the instrument's appearance.

Critical Safety Precautions

Read manual, use approved accessories, avoid contact with high voltage terminals, and manage test stick.

Handling High Resistance Measurements

Use shield terminal G for high insulation resistance or surface leakiness issues to ensure accurate readings.

Testing Procedures and Safety

General Testing Precautions

Ensure no charge in circuitry, wear insulation gloves, and do not measure with battery cover open.

Test Lead Connection

Connect test leads to L, E, and G terminals correctly for testing insulation resistance.

Rated Voltage Selection

Select the appropriate rated voltage (250V, 500V, 1000V for HDT20A; 500V, 1000V, 2500V for HDT20B).

Testing Operation and Range Selection

Press TEST, check HV ON indicator. Select appropriate range (200MΩ or 2GΩ) for accurate readings.

AC Voltage Measurement

Select ACV, connect leads to ACV jack and G input, and read voltage within specified limits.

Battery Replacement and Storage

Low Battery Indication

Replace battery when the low battery symbol appears on the LCD.

Battery Replacement Procedure

Stop testing, turn off, remove lines, open cover, insert 6 LR6/UM-3 batteries, replace cover.

Instrument Storage Guidelines

Turn off, remove batteries for long-term storage. Keep clean, store in a dry, ventilated place.

Accessory Information

HDT20 A Accessories

Includes plastic cover, test lead (with clip), manual, and warranty card.

HDT20 B Accessories

Includes plastic cover, test lead (with clip), manual, warranty card, and shielding line.

Hongda USA HDT20A Specifications

General IconGeneral
ModelHDT20A
ManufacturerHongda USA
TypeDigital Multimeter
DisplayLCD
Continuity TestYes
Diode TestYes
Battery Type9V
Current Range200µA/2mA/20mA/200mA/10A