DISPLAY ALARMS P3 and P2
The alarm and active function codes shown on the di-
splay when the machine is in operation are:
- A 4: TEMPERATURE PROBE DISCONNECTED
This alarm message appears if either or both of the
probe contacts are disconnected
(or if the probe is interrupted);
- A5 : BOILER OVERHEATING
This alarm message appears when the temperature
in the boiler exceeds 99°C o circuit short;
3.2 DETERGENT DISPENSER (Optional)
The machine is equipped with an automatic detergent
dispenser.
• Insert the supply tube into the cannister.
ATTENTION
Always wash the hands under running water if they come
into contact with detergent, or comply with the specic
indications pertaining to the utilized type of detergent.
• The detergent inlet is automatic at every water ll-in
in the tank.
To adjust the dispenser, refer to the relative enclosed
manual and to the utilized type of detergent.
To connect the detergent pump, use the specic termi-
nals inserted in the electrical system.
3.3 FILLING THE RINSING AGENT
DISPENSER
• Insert the tube into the cannister containing rinsing
agent.(Refer to the specic instructions given with the
rinsing agent itself).
• Start the machine as described in paragraph 2.1.
The dispenser will suck about 3 cm of liquid from the
cannister.
• Fill during the cycle by opening (slightly) and closing
the door until the tube has completely lled.
3.3.a Adjusting the dose
• Start the machine as described in paragraph 2.1 amd
hold a glass up to the light at the end of the cycle.
• The drops of water on the glass will indicate insufcient
dosage while, the streaking or spotting will indicate,
instead, an excessive dosage.
• Regulate by means of the plug , turning clockwise to
decrease the quantity or anticlockwise to increase it.
IMPORTANT
These data are indicative and not binding since they may
vary according to the hardness of the water or the utilized
type of detergent and rinsing agent.
ATTENTION
If the utilized product (detergent or rinsing agent) is
changed, it is advisable to ush out the dosing system
with water and to then proceed by lling the dispensers.