If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the check list below.
What's the problem? Cleaner won't turn on.
[What's the cause? What's the solution? ]
Not firmly plugged in. Plug unit in firmly.
No voltage in wall plug. Replace fuse or reset circuit.
What's the problem? Agitator brush roll brushes aren't turning.
[What's the cause? What's the solution? j
Hard Surface mode selected on Surface Selector Select a suitable carpet mode setting.
control dial.
Agitator brush roll is obstructed.
Disconnectcleaner from electrical outlet. Turnc]eaner over and
remove any debris that hasaccumulated on the agitator brush
roll.
[What's the cause?
Filter bag full.
Incorrect carpet height setting.
Blockage in system.
What's the solution?
Change filter bag.
Selectanother carpet height setting on the Surface Selector
control dial,
Clear blocl<age(see"Clearing blockages" section),
[What's the cause? What's the solution? ]
Incorrect carpet height setting. Select a hi_her carpet height setting on the Surface Selector
control di_[.
What's the problem? Cleaning tools won't pick up.
[What's the cause? What's the solution? j
Filter bag full. Change filter bag.
Blockage in system. Clear blockage (see "Clearing blockages" section).
What's the problem? Powered pet hair cleaning tool agitator brush roll won't turn.
[What's the cause? What's the solution? ]
Too much pressure being applied to tool.
Blockage in turbine channel.
Broken or worn belt.
Low cleaner suction.
Continue using tool applying light pressure.
Remove blockage.
Rep]ace be]t.
Refer to items under "Cleaner won't pick up".