OCS-I/O - CSCAN COMMUNICATION BASE
page 1 of 2
HE959CNX116
2 Flexible Inputs (Digital/Analog), 2 Digital Outputs,
1 Universal Analog Input, 1 Analog Output
TECHNICAL SPECIFICATIONS
1.1 General Specifications
Required Power (Steady State)
630mA @24VDC (<15W @ 24V)
Required Power (Inrush)
24A @ 30 μS
Primary Power Range
10-30VDC
Flex Inputs (Digital or Analog)
2
Digital Outputs per Module
2
Analog Inputs
1
Analog Outputs
1
Relative Humidity
5-95% non-condensing
Port Wiring
(Analog Inputs and Digital I/O)
16-24 AWG / 0.2-1.4mm²
Operating Air Temp
-40°C (-40°F) to 60°C (140°F)
Storage Temp
-40°C (-40°F) to 85°C (185°F)
Weight
87g (3.05 oz)
Dimensions
76.5mm x 124.5mm x 19mm
3” x 4.9” x 0.75”
Certifications
(UL/CE)
North America: https://hornerautomation.com/
certifications/
Europe: https://www.hornerautomation.eu/
support/certifications-2/
1.2 Connectivity
CAN Protocols
CsCAN - IN and OUT
1.3 Universal Analog Inputs
Number of Channels
1
Input Ranges
0-10V / 0-20mA / 4-20mA / 0-60mV
0-10V / 0-20mA / 4-20mA /
0-60mV
16 Bit
%AI Full Scale
0.20%
Thermocouple
J / K / T / N / E / R / S / B
Converter Type
16-Bit ADC
RTD
PT100 / PT1000
RTD Excitation Current
.250mA
1.4 Digital Outputs
Inputs per Module
2
Commons per Module
1
Output Type
Sourcing with 10kΩ pull down
Absolute Max Voltage
28VDC
Output Protection
Short Circuit
Max Output per Point
2A
Max. Total Out Current
4A
Max. Output Supply Voltage
30VDC
Min. Output Supply Voltage
10VDC
Max Voltage Drop at rated Current
550mV
Min Load
1mA
OFF to ON Response
1ms
ON to OFF Response
1ms
I/O Indication
Status LED per Output
1.5 Analog Outputs
Number of Channels
2 Analog
Analog Outputs
0-20mA / 4-20mA / 0-10V
Analog Output Data Ranges
0~4000 / -2000~2000 /
0~1000 / 0~2000/ 0~32000
Nominal Resolution
12 Bit
Minimum 10V Load
500Ω
Maximum Current Load
500Ω
Analog Output Halt State
Current / Minimum /
Maximum / Median
1.6 Flexible Inputs - Digital / Analog
Number of Channels
2 (Digital or Analog)
Configured as Analog I/O
Analog Input Ranges
4-20mA / 0-10V
Analog Input Data Ranges
0~4000 / -2000~2000 /
0~1000 / 0~32000
Alarm
Value / Register
Configured to Digital Inputs
Digital Input Ranges
24V / 12V / 5V / Custom
Input Voltage Range
0 - 24VDC
Absolute Max Voltage
+/- 30VDC
Input Impedance
10kΩ
Custom Digital Input Ranges
Threshold ON
Threshold OFF
OFF to ON Response
1ms
ON to OFF Response
1ms
Digital Input Active Mode
Positive / Negative Logic
Connector Type
Phoenix Contact 2202234
Question and Answer IconNeed help?

Do you have a question about the HORNER HE959CNX116 and is the answer not in the manual?

HORNER HE959CNX116 Specifications

General IconGeneral
BrandHORNER
ModelHE959CNX116
CategoryConference System
LanguageEnglish

Summary

General Specifications

Required Power

Specifies the steady state and inrush power requirements for the module.

Primary Power Range

Defines the acceptable voltage range for the module's primary power supply.

Flex Inputs

Details the number of flexible inputs, configurable as digital or analog.

Digital Outputs

Specifies the number and characteristics of the module's digital outputs.

Analog Inputs

Details the number and type of analog inputs supported by the module.

Analog Outputs

Specifies the number and type of analog outputs provided by the module.

Environmental Specifications

Covers operating and storage temperature, and relative humidity limits.

Connectivity

CAN Protocols

Identifies the supported CAN communication protocols.

Universal Analog Inputs

Input Ranges

Lists the available input voltage and current ranges for universal analog inputs.

Converter Type

Specifies the analog-to-digital converter type and resolution.

Digital Outputs

Output Type

Describes the output type, including sourcing and pull-down configuration.

Output Protection

Details the protection features for the digital outputs, such as short circuit protection.

Response Times

Specifies the OFF to ON and ON to OFF response times for digital outputs.

Analog Outputs

Analog Output Data Ranges

Lists the available data ranges for analog outputs (voltage and current).

Nominal Resolution

Specifies the resolution of the analog output conversion.

Flexible Inputs - Digital / Analog

Configured as Analog I/O

Details configuration options when inputs are set as Analog I/O.

Configured to Digital Inputs

Details configuration options when inputs are set as Digital Inputs.

Installation

Module Mounting

Describes how to mount I/O modules onto a DIN-rail.

Hot Swapping Capability

Information on adding or removing modules while the system is powered.

Safety Warnings

General Safety Precautions

Important warnings regarding equipment use, explosion hazards, and component substitution.

Output Wiring Safety

Guidelines for connecting outputs to appropriate voltage levels and power sources.

Technical Support

Contact Information

Provides contact details for technical assistance and manual updates in North America and Europe.

CAN Table

CAN Pin Assignments

Details the pin assignments for the CAN interface, including signal names and descriptions.

Wiring

Powering the Base

Guidance on powering the OCS-I/O HE959CNX16 Base independently from modules.

Network Wiring

Recommendations for network wiring, including daisy-chaining, shield connections, and termination resistors.

Onboard Wiring

Diagrams and labels for onboard wiring connections, including CAN ports and I/O.

CsCAPE Configuration

General Configuration Procedure

Step-by-step guide for configuring the OCS-I/O base and modules using Cscape software.

Module Configuration Details

Details on configuring individual I/O modules, including input/output mapping and communication timeouts.

Status Registers

Register Map

Provides a layout of status registers and their corresponding bits for I/O modules.

Register Bit Definitions

Explains the meaning of individual bits within the status registers (e.g., CME, IOE, WDG TRIP).

Alarm Status Table

Defines the alarm states (Low-Low, Low, Normal, High, High-High) based on alarm bits.

Diagnostic LED Indicators

System LED Indicators

Describes the status of system-level LEDs (Power, Self-Test, Network, Configuration).

Individual I/O Channel LEDs

Explains the meaning of LEDs for individual I/O channels (Digital Inputs/Outputs, Analog Inputs/Outputs).