- During InitializationSensors are (OF / Off; on / On)
- Power FailOption (0P / Open; [L - Close)
- Braking (OF / Standard; on / SlowerBraking)
ACTUATING & CONTROL SWITCH CONNECTIONS TO C2150 INDUSTRIAL CONTROL
- EngageLock at full open.
UP
4 - WHITE (MONITORSW)
3 - GREEN (NOT USED)
2 - RED (LOCK ENABLE)
1 - BROWN (+24VDC)
AUTOLOCK CONNECTOR:
WHENUNITIS IN NORMAL OPERATION, THE DOWNPUSHBUTTONWILL ACTUATE CONTROL.
PRESS & HOLD THE UP PUSHBUTTON, THEN PRESS THE DOWNPUSHBUTTON & RELEASE BOTHWILL INITIATESELF-CYCLE.
5 - BLACK (COMMON)
- Slow Speed Open Parameters
PERMANENTLYSTORE, TURN TOGGLE SWITCH "ON",PRESS AND HOLD SET UNTIL DSIS DISPLAYED.
FIND PARAMETER;PRESS SET TO DISPLAY CURRENT SETTING. PRESS & HOLD SET & USE UP / DOWNTO CHANGE SETTING. RELEASE SET BUTTON. TO
SETTINGS WILLBE LOST, AND CONTROL WILLREVERTTO DEFAULT SETTINGS. TO READJUST, TURN OFF TOGGLE SWITCH, USE UP / DOWN BUTTONS TO
THEN SLOWLY OPEN TO FULL OPEN, DISPLAY MEASURED STROKE IN INCHES, THEN RESUMENORMAL OPERATION. ALL PREVIOUSLY STORED
TO REINITIALIZE CONTROL PRESS SET & RESET SIMULTANEOUSLY, RELEASE RESET, WAIT 5 SECONDS,THEN RELEASE SET;UNITWILL POWER CLOSE,
SW) * NOTE: IF 3-BUTTON STATION NOT
STOP CONTACT *(N.C.) TO #15 & #16 (KEY
on; OPEN CONTACT (N.O.) TO CONNECT
- Horton Lock Installed (90vdc)
- BiStable Autolock (oF / StandardLock Style; on / BiStable)
- Unmonitored Autolock (oF / Switch Present; on / No Switch)
- Autolock Type (oF / Fail Secure; on / Fail Safe)
- Automatic Lock Present (oF / Off; on / Horton Autolock)
- Three Button Station enabled
- Reduced Acceleration Mode
3 - BUTTON STATION: SET 3T OPTION
C1884
Sensor
(Eagle)
Y
R
Y
R
Y
R
IN USE,JUMPER BETWEEN #15 & #16.
H603.10
- Open Speed (00 - 15)
- CloseSpeed (00 - 15)
- Close Check (00 - 15)
- Open Cushion (00 - 15)
- Open Check (00 - 15)
- Auto Seal
- Cycle Test Unit
- Partial Open TimeDelay(00 -199sec.)
- Full Open Time Delay (00 -199sec.)
- Total Stroke
- Partial Open CutoffPoint
- Open Check Point (inches)
- Reverse Open TimeDelay
- Close Cushion (00 - 15)
DISPLAY CODES OF ADJUSTABLE PARAMETERS:
NC
54321
2&3
Jumper
- Brake on Recycle
- FastOpen Mode
- Freezer Track Start
- Safety Nosing
SWITCH
ON / OFF
TOGGLE
SWITCH (WIRED
WHT
BLK(+24VDC)
GRN
FOR PARTIAL OPEN
)
PUSH PLATE
C1260
SWITCH
PULL TO CLOSE
PULL TOOPEN
-
(OVERIDES TIME
DELAY ACTUATION)
PULLTO
PULLTO
CLOSE
OPEN
PULL
C499-1
CHAIN
WHT
BLK
BLU
BLK
BRN
RED
GRN
12 PART'L OPEN
R
SW
12
CONTACT (N.O.) TO #14 & #15 (SW C);
BETWEEN #3 & #4 (EXT MOT);CLOSE
SWITCH BETWEEN #12 & #15 (SW A)
PARTIAL OPEN ENABLE: ADD
CLOSE
MONITOR
SWITCH
13 (RESERVED)
16 STOP (3 BTN)
14 CLOSE (3 BTN)
15 COMMON
O
SW
C
KEY
13
16
15.
14
BEM
MOT
MOT
MON
10 CLS MON SW
3 LATCHFUNCT
2 MOMENTARY
5 +24VDC
11 COMMON
9 COMMON
7 COMMON
6 SAFTYBEAM
8 TOGGLE SW
4 COMMON
1 +24VDC
SW
Y
Y
Y
G
G
R
G
SW
B
A
SW
INT
TOG
CLS
SAF
EXT
9.
8
7.
6
10
4.
2
3
1
5
11.
RESET
VER 3.XX
- EncoderPhasing Wrong
- Dimple Track Start Error (delays & retries)
- BatteryFailure (if Power FailOption present)
- Stroke Determination Failure
- Lock Failure of Automatic Lock
- Unlock Failure of Automatic Lock
- Close Monitor Switch notFound
ERROR AND TEST DISPLAYCODES:
- Loss of Encoder Pulses
- Data Storage Failure
- Encoder Failure
- Pedestrian Stopping Initialization
Corpus Christi, Texas 78405
- Door Latched Open
- Partial Open Check (when activated)
- Data Stored
- Control is Braking Motor
- Idle Mode (Executive)
- Encoder Test Initiated
- Door Stopped by 3-ButtonStation
ADDITIONAL CODES NOT ADJUSTABLE:
4242 Baldwin Blvd.
Horton Automatics
(361) 888 - 5591
--
11106.1
19950915 David Hewitt
20000825Darren Hatch
- First Run / Finding FullyOpen
- First Run / Finding Fully Closed
- Fail Safe Autolock Found
- Fail Secure Autolock Found
- No Autolock Found
INITIALIZATION CODES:
REVERSING
SENSITIVITY
2 - BROWN (MOTOR COMMON)
1 - WHITE (+90VDC)
POWER SUPPLY CONNECTOR:
4 - BLACK (COMMON)
3 - RED (+24VDC)
5 - GREEN (GROUND)
BATTERY
DOWN SET
1 - RED (+5VDC)
ENCODER CONNECTOR:
4 - BLACK (COMMON)
3 - WHITE (CHANNEL B)
2 - GREEN (CHANNEL A)
LOCK
ULK
MON
COM
+24
LOK
ENC
µSW
GND
+5
AUX
R
+100
LOCK
LOCK
MON
EXPAND
O
Y
R10
GND
MOTOR CONNECTOR:
2 - RED
1 - BLACK
3 - GREEN/YELLOW (GROUND)
K1
JU1
K2
MOTOR
TO C3955 / C3956POWER SUPPLY
3
K3
C2150
HORTON
1 2
1
54