Cleaning Prep:
Remove the Front Panel, move the control switch to OFF.
After 3 min., move the switch to ICE, then replace the panel
.
After 3 min., remove the Front Panel, move the switch to OFF.
Remove all ice from the ice storage bin and/or dispenser.
WARNING! IF ON DISPENSER, turn off the dispenser power
supply after dispensing all the leftover ice.
Cleaning:
Remove the Base Cover, disconnect the Pump Tubing. After the water tank has
drained, reconnect Pump Tubing. Do not replace the base cover at this time.
Refill water tank by moving the control switch to ICE,
replace the Front Panel. After 3 minutes, remove the
Front Panel, then move the control switch to OFF.
Remove the Front Insulation Panel. Pour 14 fl.oz
(414 ml) of Hoshizaki Scale Away into the water
tank. Replace the Front Insulation Panel. Turn the
cleaning valve left until completely vertical (open).
NOTICE! AVOID EXCESSIVE FOAMING, wait
1 minute before next step.
Move the control switch to WASH, replace Front
Panel.
KM-515MAH, MWH, MRH
KM-600MAH
KM-650MAH, MWH, MRH
KM-901MAH, MWH, MRH/3
3
min.
Sanitizing:
• Fill the water tank
• CLOSE the cleaning valve
• Move control switch to ICE,
replace the front panel
• After 3 minutes, remove the
front panel
• Move control switch to OFF
• Remove the front insulation
panel
• Pour .78 fl. oz (23 ml) of
chlorine bleach* into the
water tank
• Replace the front insulation
panel
• OPEN the cleaning valve
* Use bleach without additives.
Additives cause excessive foaming, and
reduces effectiveness of the cleaning.
• Wait 1 minute to avoid
excessive foaming
• Move control switch to WASH,
replace the front panel
• After 45 minutes, remove
the front panel
• Move control switch to OFF
• Disconnect the pump
tubing
• After the water tank has
drained, reconnect the pump
tubing
min
min.
AMMONIA
Cleaners
The ice maker must be cleaned & sanitized at least once a year.
WARNING!
DO NOT leave icemaker
unattended when panels are off
Tech Support: 1.800.233.1940
1
2
3
4
14
15
16
17
18
5
6
7