Front of Icemaker
(KML-351MAH shown)
Cleaning Prep:
Remove the Front Panel, move the control switch to
OFF. After 3 min., move the control switch to ICE, then
replace the Front Panel
.
After 3 min., remove the Front Panel, move the
control switch to OFF. This removes the cubes from
the evaporator.
Remove all ice from the dispenser unit/ice storage bin.
ATTENTION! IF ON DISPENSER, turn off the dispenser
power supply after dispensing all the ice.
Cleaning:
Remove the Front Panel, move the service switch to
DRAIN. Move control switch to SERVICE. Replace
the Front Panel.
After 2 minutes, remove the Front Panel, move the
control switch to OFF.
Dilute Hoshizaki Scale Away with warm water (see Table below).
Remove the Front Insulation Panel and pour cleaning solution
into the water tank. Replace the Front Insulation Panel.
KML-250MAH, MWH
KML-351MAH, MWH
KML-451MAH, MWH
KML-631MAH, MWH, MRH
Sanitizing:
Dilute 5.25% chlorine
bleach* with warm water
(see Table below)
* Use bleach without additives.
Remove the front insulation
panel
Pour the sanitizing solution
into the water tank
Replace the front insulation
panel
Move service switch to
WASH and control switch to
SERVICE, replace the front
panel
After 15 minutes, remove
front panel
Move service switch to DRAIN,
replace the front panel
After 2 minutes, remove
front panel
Move control switch to OFF
The icemaker must be cleaned & sanitized at least once a year.
ATTENTION!
Do not leave icemaker
unattended when panels are off