TECHNICAL DATA
Gas connection Rp
1
/
2
(
1
/
2
" BSP female)
Pressure test point Front left hotplate injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection 4mm
2
twin and earth
230/240V a.c. 50Hz. 13A fuse.
HEAT
INPUT
G20 at 20mbar
G30 at 28-30mbar
G31 at 37mbar
BURNER
INJECTOR
2.4 / 2.7 kWGRILL
1.8 / 2.0 kWMAIN OVEN
1.7 / 1.9 kW
TOP OVEN
3.0 kWHOTPLATE
Front left and rear right
116
2.0 kWHOTPLATE
Front right and rear left
103
HEAT
INPUT
INJECTOR
3.0 kW (220g/h) 86
2.0 kW (145g/h) 70