OPERATIONAL CHECKS
After installation, check for gas soundness. The supply pressure can be checked
at one of the hotplate burner injectors.
Check that the hotplate burners ignite correctly and burn with a steady flame.
Check for a steady flame at the low setting.
Instruct the user on operation of the cooker.