The Hozelock Cyprio Cascade 1500
pump is designed for submersible use only.
The pump does not use oil or grease for
lubrication and can be used safely in ponds
containing fish or plants. The motor consists
of a sealed stator and water-cooled
permanent magnet rotor. All electrical
components are isolated from the water.
IMPORTANT
1. WARNING: ALWAYS UNPLUG OR
DISCONNECT ALL APPLIANCES IN THE
POND FROM THE ELECTRICITY SUPPLY
BEFORE PUTTING YOUR HANDS IN THE
WATER WHILST EQUIPMENT IS BEING
INSTALLED, REPAIRED, MAINTAINED OR
HANDLED.
2. Do not use the supply cable to lift the
pump, as this may cause damage. We
recommend fitting a lifting cord to the
handle eye on the top of the strainer cage
when the pump is installed in deep water.
3. Do not operate or leave the pump in
freezing conditions.
4. Do not allow the pump to run dry.
5. Check that the voltage marked on the
pump corresponds to the mains supply.
6. A 10MA OR 30 MA RESIDUAL CURRENT
DEVICE MUST
BE FITTED TO THE MAINS
SUPPLY.
7. DO NOT OPERATE THIS PUMP
WITHOUT THE STRAINER CAGE
ATTACHED. USING THE PUMP WITHOUT A
STRAINER CAGE MAY INVALIDATE YOUR
WARRANTY.
Safety Information
The appliance is not intended for
use by persons (including children)
with reduced physical, sensory or
mental capabilities, or lack of
experience and knowledge, unless
they have been given supervision or
instruction concerning use of the
appliance by a person responsible
for their safety. Children should be
supervised to ensure that they do
not play with the appliance.
(Australia & NZ only) This appliance
is not intended for use by young
children or infirm persons unless
they have been adequately
supervised by a responsible person
to ensure that they can use the
appliance safely.
Young children should be supervised
to ensure that they do not play with
the appliance.
WARNING: SAFETY AND
ELECTRICAL CONNECTIONS
1. The pump is supplied with 10m of 3 core
electric cable which is permanently
connected and sealed to the motor.
The supply cable cannot be replaced. If the
cable is damaged, the pump should be
discarded.
This product is designed to be
permanently wired to the mains supply in
a dry weatherproof enclosure through a
Double-Pole Switched Fused Spur -
(Disconnector) to BS 3676, with a
minimum contact separation of 3mm in
each Pole - Fitted with a 3 or 5 Amp fuse.
The installation must conform to the
national and local wiring regulations
which could include the use of plastic or
metal conduit to protect the cable.
2. A 10MA OR 30MA RESIDUAL CURRENT
DEVICE (RCD) MUST
BE FITTED TO THE
MAINS SUPPLY.
3. WARNING: THIS APPLIANCE MUST
BE
EARTHED AND IT IS ESSENTIAL THAT THE
CONNECTIONS ARE MADE USING THE
FOLLOWING CODE;
Brown - Live
Blue - Neutral
Green/Yellow - Earth
The BROWN lead should be connected to
the LIVE terminal which may be marked
with an ‘L’ or coloured brown or red.
The BLUE lead should be connected to the
NEUTRAL terminal which may be marked
with an ‘N’ or coloured blue or black.
The GREEN/YELLOW lead should be
connected to the EARTH terminal which
may be marked with an ‘E’ or coloured
green or green/yellow.
4. If an extension cable is required, this
should be connected to the end of the
pump cable using a weatherproof cable
connector. The joint must be positioned in
a suitable weatherproof housing. The
extension cable should be of 3 core
0.75mm
2
Polychloroprene rubber insulated
cable (ref: HO5 RN-F) and permanently
wired to the mains supply with a 3 or 5
Amp fuse.
5. The pump cable (and extension cable)
should be positioned and adequately
protected against damage especially
where contact with gardening equipment
(lawn mowers, forks etc.) children and
domestic animals may occur.
6. CONSULT A QUALIFIED ELECTRICIAN OR
LOCAL AUTHORITY IF IN ANY DOUBT
ABOUT WIRING TO THE MAINS SUPPLY.
ACCESSORY ASSEMBLY
Tee Piece
1. Locate the fountain flow adjuster (See
Fig1-A) to the tee piece body with the peg
positioned downwards to engage in the
tee. Push in fully and snap them together.
2. Locate the valve stem (B) to the waterfall
flow adjuster (C) and snap them together.
Screw the valve assembly into the longer
boss (D) on the tee piece. See fig 1.
Telescopic Stem
1. Slide the Inner Tube (E) through the
Telescopic Stem Nut (F) and “O” ring (G).
Push the Inner Tube into the Outer Tube
(H) and gently screw down the nut. The
finishing position of the tee piece is not
important. The maximum to minimum
range of the Telescopic stem is 150mm
(6”) (See fig 2).
Bell Fountain
1. Locate the Bell Support (I) to the Bell Main
Body (J) and push fully home.
2. Position the Bell (K) to the Body Assembly
and press into the central location.
See fig 3.
PUMP INSTALLATION
Position
Construct a solid and level platform on which
to place the pump. For installations using the
fountain tops directly on the Tee Piece, the
top level of the platform should be 300 mm
(12”) below the water level. For installations
using the fountain tops directly on the Tee
Piece and Telescopic Stem , the top level of
the platform should be 450 mm (18”) below
the water level.
Fountain Only. (See Fig 7 for general
installation guide)
1. Place the pump next to the pond and
route the cable back to the mains supply.
2. Position the pump with the Tee Piece
Assembly and if required the Telescopic
Stem with the fountain fitted in the
desired position in the pond. The 2 and 3
tierfountain heads simply snap onto the
fountain stem (See Fig 4).
3. The fountain height can be regulated to
suit your needs by rotating the Fountain
Flow Adjuster. See Fig 5 (L).
4. If required, the 2-Tier Fountain head, Fig 5
(M), can be used to achieve an alternative
and higher display pattern than the 3-Tier,
Fig 5 (N).
5. The Bell Fountain creates a decorative
waterbell. The size of the bell can be
regulated by adjusting the flow through
the Tee Piece by rotating the fountain
flow adjuster and or by raising or lowering
Cascade 1500
INSTALLATION AND OPERATING INSTRUCTIONS. READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
3354
ATTENTION
AUTOMATIC CUT-OUT. To help ensure
your pump’s long life and to prevent
damage, it is fitted with automatic
thermal overload protection. This
switches off the pump if it overheats. If
this occurs, switch off the power at the
mains supply to the pump. Check for the
cause. Usually it will be debris blocking
the inlets of the pump or obstructing the
impeller. Remove the obstruction and
wait 15 minutes for the pump to cool
down and automatically reset. Then
switch on the pump again.
NOTE: YOU MUST SWITCH OFF THE MAINS
SUPPLY BEFORE THE PUMP WILL RESET.
From 1st January 2005 installing this
product in the garden is classed as
'notifiable' in the revised Building
Regulations for England and Wales. The
Regulations now require you to tell
your local authority building control
department that you intend to install
this product before installation. Your
local authority will let you know how
you can get your installation approved.
Question and Answer IconNeed help?

Do you have a question about the Hozelock Cyprio Cascade 1500 and is the answer not in the manual?

Summary

Automatic Cut-Out and Safety Information

Automatic Cut-Out

Automatic thermal overload protection switches off the pump if it overheats, requiring manual reset.

Safety Information

Intended use for persons with reduced physical, sensory, or mental capabilities requires supervision.

Safety and Electrical Connections

Cable and Wiring

Pump cable is permanently connected. Installation requires specific wiring and protection.

Residual Current Device (RCD)

A 10mA or 30mA RCD must be fitted to the mains supply for safety.

Wiring Connections

Ensure appliance is earthed using correct colour codes for Live, Neutral, and Earth.

Extension Cable Requirements

Extension cables must be weatherproof, of specific type, and permanently wired.

Cable Protection

Pump cable must be protected from damage by gardening equipment or domestic animals.

Consultation Advice

Consult a qualified electrician or local authority if unsure about mains wiring.

Accessory Assembly

Tee Piece Assembly

Instructions for assembling the tee piece and fountain flow adjuster.

Telescopic Stem Assembly

Steps to assemble the telescopic stem for adjustable fountain height.

Bell Fountain Assembly

Guide to assembling the bell fountain components for a waterbell effect.

Pump Installation

Pump Positioning

Place pump on a solid, level platform below the water level as specified.

Fountain Only Installation

Steps for installing the pump for fountain-only operation with accessory assembly.

Fountain and Waterfall Installation

Guide to setting up for both fountain and waterfall effects.

Waterfall Only Installation

Instructions for installing the pump for waterfall-only operation.

Maintenance and Care

General Maintenance

Always disconnect power before maintenance. Clean strainer and fountain head regularly.

Fountain Head Cleaning

How to remove, rinse, and reassemble the fountain head for optimal performance.

Strainer Cleaning

Instructions for removing, cleaning, and reassembling the strainer cage.

Rotor Assembly Cleaning

Steps to remove, clean, and reassemble the rotor assembly and pump chamber.

All Year Pump Care

Daily Checks

Perform a quick daily check to ensure the pump is performing satisfactorily.

Weekly Cleaning

Clean strainer cage and fountain head weekly, or more often if conditions require.

Annual Overhaul

Disassemble pump annually, wash components, and replace any worn or broken parts.

Guarantee and Fault Finding

Spare Parts

Contact the Consumer Services Helpline for spare parts.

3 Year Guarantee Terms

Details of the 3-year guarantee, repair/replacement policy, and exclusions.

Fault Finding: Low Flow

Troubleshoot low flow by checking strainer, outlet pipe, and blockages.

Fault Finding: No Flow

Troubleshoot no flow by checking power, fuse, wiring, and rotor assembly.

Fault Finding: Poor Display

Address poor fountain display by cleaning the fountain head.

Hozelock Cyprio Cascade 1500 Specifications

General IconGeneral
Max Flow Rate1500 L/h
Max Head1.8 m
Power Consumption25 W
Cable Length10 m
Wattage25 W