Model
1630A/D/G

Display
Messages
INSERT
to
check
for
disc
-
This
message
is
displayed
when
the
cursor
is
in
the top
row
of
the
Storage
Operations
menu
.
Pressing
INSERT
will
cause
the
analyzer
to
see
if
a
disc
is
present
at
the
assigned
HP-IB
address
and
unit
.
INSERT
to
confirm
-
Before
the
current operation
can
continue,
INSERT
must
be
pressed
to
confirm
that
the
selected
operation
is
desired
.
INSERT
to
inverse
assemble-This
message
is
displayed
in
thestate
list
menu
when
certain
inverse
assemblers
are
active
.
the
current
inverse
assembler
cannot
accurately
determine
where
the
first
state
of
an
instruction
fetch
is
.
Position
the
display
so
that
the
state
aligned
with
the
inverse
video
line
number
is
the
first
state
of
an
instruction
fetch
.
Press
INSERT
to
start
the
inverse
assembly
from
the
indicated
state
.
INSERT
to
overwrite
-A
request
has
been
made
to
overwrite
a
disc
file
.
Before
the old
file
is
destroyed,
INSERT
must
be
pressed
to
overwrite
it
.
INSERT
to
start
operation
-
This
message
is
displayed
when
the
cursor
is
in
the
bottom
row
of
the
Storage
Operations
menu
.
Pressing
INSERT
will
cause
the analyzer
to
begin
the currently
selected
operation
.
INSERT
to
store
compare
image
-This
message
is
displayed
in
the
state
full
compare
list
menu
when
viewing
the
trace
data
.
Press
INSERT
to
store
the
current
trace
data
as
the
compare
image
.
Internal
message
error
-
Indicates
internal
problems
with
the
analyzer
.
Record
events
leading
up
to
this
message
and
contact
Hewlett-Packard
.
Invalid
clock
setting
-
This
message
is
displayed
when
the
analyzer
clock
in
the
SYSTEM
[Peripherals]
menu
has
not
been
set
to a
correct
date
.
The
clock
date
mustbe
later
than
December,
1981
.
NOTE
:
Compare
list
is
empty-This
message
is
displayed
when
the
state
Compare
traced
mode
is
selected
and
the
list
in
the
compare
memory
has
no
entries
.
NOTE
:
Cursor
correlation
is
not
available
-
This
message
will
appear
during
interactive
state/timing
measurements
if
conditions
other
than
State
Master
and
Timing
Don't
Care
are
set
up
.
For
example
if
state
is
master
and
timing
is
set
to
trigger
on
a
pattern
or
glitch
.
NOTE
:
No
stored
compared
image
-This
message
is
displayed
when
the
state
Full
Compare
mode
is
selected
.
NOTE
:
Trace
data
has
less
states
than
compare
image
.
This
message
is
displayed
in
the
trace
compare
modes
when
the
trigger
is
centered
on,
or
ends
the
trace
.
NOTE
:
Trace
data
has
more
states
than
compare
image
.
This
message
is
displayed
in
the
trace
compare
modeswhen
the
trigger
is
centered
on,
or
ends
the
trace
.
Max
43
"'s
per
label
-
State
format
labels
can
have
a
maximum
of
43
bits
allocated
.
One
"
'
required
for
each
label
-
This
message
is
displayed
when
a
name
for
a
new
label
has
been
created
before
assigning
the
first
bit
to
be
identified
by
that
label
.
Operation
aborted
-
The
current
operation
has
been
aborted
.
Example
:
occurs
when
STOP
is
pressed
during a
save
configuration
to
internal
storage
.
Power-up
complete
-
This
message
is
displayed
after
the
analyzer
has
successfully
completed
the
power-up
test
routine
.
Reading
directory
-
The
analyzer
is
reading
the
directory
on
the
external
mass
storage
device
.
ROLL
to
change
configuration
-
This
message
is
displayed
when
in
the
SYSTEM
[Configuration]
menu
.
It
prompts
use
of
the
ROLL
keys
to
change
the
distribution
of
input
bits
between
the
state
and
timing
measurement
channels
.
A-
5